Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint / (Record no. 13063)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02092nas a22002537a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20210315161352.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 171219t2021 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | 1350-4533 |
040 ## - CATALOGING SOURCE | |
Transcribing agency | Salus Infirmorum |
245 00 - TITLE STATEMENT | |
Title | Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint / |
Statement of responsibility, etc. | Sagrario Pérez-de la Cruz, Óscar Arellano de León, Néstor Pérez Mallada, Antonio Vargas Rodríguez |
500 ## - GENERAL NOTE | |
General note | PDF en biblioteca |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliografía: p. 10-11 |
520 8# - SUMMARY, ETC. | |
Summary, etc. | Aim: The aim of this study was to establish the validity of an external measurement system (the Hawk goniometer). This is a digital device which measures joint ranges compared to the universal goniometer for the measurement of shoulder range of motion in healthy adults.<br/>Material and methods: a correlational study with 157 healthy volunteers completed six shoulder movements (forward flexion, abduction, extension, adduction and internal and external rotation) with each shoulder. The degree of agreement between each goniometer and Hawk measurement was assessed using Intra-class Correlation Coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA).<br/>Results: the tests showed a very strong relationship between the readings of both devices (CI between 0.81 and 0.99) and there were no significant differences between the mean readings of both devices.<br/>An intraclass correlation coefficient (ICC) of above 0.9 was obtained, indicating a high intra-evaluator reliability of the Hawk goniometer in repeated measurements of shoulder range of motion.<br/>Conclusions: the Hawk goniometer is a valid and reliable element for the objective measurement of the range of motion at the shoulder joint. |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Hawk goniometer |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Universal goniometer |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Range of motion |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Assessment |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Shoulder |
773 ## - HOST ITEM ENTRY | |
Related parts | -- 2021, v. 89, p. 7-11 |
Title | Medical Engineering and Physics |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Universal Decimal Classification |
Koha item type | Artículo de revista |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Home library | Current library | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal Decimal Classification | Non-fiction | Revistas y artículos | Revistas y artículos | 19/02/2021 | PP | 5706 | 19/02/2021 | 19/02/2021 | Artículo de revista |