Facultad de Enfermería y Fisioterapia Salus Infirmorum

Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint / (Record no. 13063)

MARC details
000 -LEADER
fixed length control field 02092nas a22002537a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210315161352.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2021 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1350-4533
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint /
Statement of responsibility, etc. Sagrario Pérez-de la Cruz, Óscar Arellano de León, Néstor Pérez Mallada, Antonio Vargas Rodríguez
500 ## - GENERAL NOTE
General note PDF en biblioteca
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 10-11
520 8# - SUMMARY, ETC.
Summary, etc. Aim: The aim of this study was to establish the validity of an external measurement system (the Hawk goniometer). This is a digital device which measures joint ranges compared to the universal goniometer for the measurement of shoulder range of motion in healthy adults.<br/>Material and methods: a correlational study with 157 healthy volunteers completed six shoulder movements (forward flexion, abduction, extension, adduction and internal and external rotation) with each shoulder. The degree of agreement between each goniometer and Hawk measurement was assessed using Intra-class Correlation Coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA).<br/>Results: the tests showed a very strong relationship between the readings of both devices (CI between 0.81 and 0.99) and there were no significant differences between the mean readings of both devices.<br/>An intraclass correlation coefficient (ICC) of above 0.9 was obtained, indicating a high intra-evaluator reliability of the Hawk goniometer in repeated measurements of shoulder range of motion.<br/>Conclusions: the Hawk goniometer is a valid and reliable element for the objective measurement of the range of motion at the shoulder joint.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term Hawk goniometer
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term Universal goniometer
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term Range of motion
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term Assessment
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term Shoulder
773 ## - HOST ITEM ENTRY
Related parts -- 2021, v. 89, p. 7-11
Title Medical Engineering and Physics
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 19/02/2021   PP 5706 19/02/2021 19/02/2021 Artículo de revista

Powered by Koha