Reliability and Concurrent Validity of the Goniometer-Pro App vs a Universal Goniometer in determining Passive Flexion of Knee / (Record no. 14864)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02297nas a22002417a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20230228124248.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 171219t2019 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | 1932-6203 |
040 ## - CATALOGING SOURCE | |
Transcribing agency | Salus Infirmorum |
245 00 - TITLE STATEMENT | |
Title | Reliability and Concurrent Validity of the Goniometer-Pro App vs a Universal Goniometer in determining Passive Flexion of Knee / |
Statement of responsibility, etc. | Alberto Melián Ortiz, Sofía Laguarta Val, David Varillas Delgado |
500 ## - GENERAL NOTE | |
General note | PDF en biblioteca |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliografía: p.33-34 |
520 8# - SUMMARY, ETC. | |
Summary, etc. | Purpose: Smartphones have become a staple in our society. <br/>They are essential not only for our day-to-day lives but also as a healthcare tool in the face of the emergence of a myriad of health-based applications. Analyze the reliability and concurrent validity of an iPhone app as compared with traditional goniometry. <br/>Methods: 21 subjects of our work centre, in 2016 had 4 measurements of their degree of knee flexion for a randomly chosen knee position: 2 by universal goniometry (UG) and 2 by the Goniometer-Pro (G-Pro) application. A different evaluator made each measurement. The radiographs were <br/>used as a gold standard to measure the actual knee flexion angle. <br/>Results: The difference between mean intra-group values was 3,148º (±2,669º) and 2,476º (±2,638º) for G-Pro. The difference between the mean intra-group values was 5.45º. <br/>Inter-observer consistency for UG was 0,990 and 0,993 for GPro; As regards validity, the values obtained were 0,976 for UG and 0,992 for G-Pro. <br/>Conclusions: The Goniometer-Pro app seems to be a reliable and accurate tool for determining the values of knee flexion. <br/>The values obtained are slightly more accurate than those of traditional goniometry.<br/>Implication: This study intend to promote the use of apps of systemic form in the health system, as a component integrated into the management of the health. This work not only compares the reliability of two methods of measurement, compare the reliability or validity with a gold standard, as it is <br/>the radiological measurement.<br/> |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | goniometry |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | smartphone app |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | knee flexion |
653 14 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | knee |
773 ## - HOST ITEM ENTRY | |
Related parts | -- 2019, v. 14, n.5, p. 1-24 |
Title | PLos One |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Universal Decimal Classification |
Koha item type | Artículo de revista |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Home library | Current library | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal Decimal Classification | Non-fiction | Revistas y artículos | Revistas y artículos | 28/02/2023 | PP | 6020 | 28/02/2023 | 28/02/2023 | Artículo de revista |