Facultad de Enfermería y Fisioterapia Salus Infirmorum

Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas = (Record no. 14288)

MARC details
000 -LEADER
fixed length control field 04860nas a22003497a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220726114131.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2020 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1138-7262
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Evaluación comparativa, mediante ensayos biomecánicos, de dispositivos de ostomía de dos piezas =
Remainder of title Comparative evaluation through biomechanical tests of two-piece ostomy systems /
Statement of responsibility, etc. Amelia Lucía Gómez Pérez, Raúl Panadero Morales, Fernando García Torres, María Jesús Solera Navarro, José Luís Peris Serra, Carlos M. Atienza Vicente, Eduardo García Blázquez
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.23
520 3# - SUMMARY, ETC.
Summary, etc. Objetivo: comparar las propiedades mecánicas de los dispositivos de ostomía de dos piezas más empleados en España (Coloplast –o Fabricante I– y Fabricante II), mediante la realización de ensayos mecánicos.<br/>Método: los ensayos se realizaron en el Instituto de Biomecánica de Valencia (IBV), empleándose una máquina universal de ensayos MTS INSIGHT/468, con unas condiciones ambientales controladas de temperatura (22-24 ºC) y de humedad (39-41%). El tamaño de la muestra para cada uno de los ensayos fue de 10 unidades para cada tipo de sistema. Se llevaron a cabo tres pruebas: 1) Ensayo de resistencia a la degradación del adhesivo en solución salina; 2) Ensayo de resistencia al estallido del canal de vaciado de las bolsas abiertas; 3) Ensayo de resistencia a la separación entre el disco y la bolsa.<br/>Resultados: en el ensayo de resistencia a la degradación del adhesivo en solución salina, los dos adhesivos, sometidos a periodos de degradación de 6 y 12 horas en solución salina a<br/>37 ºC, presentaron diferencias significativas a favor del Fabricante I (Coloplast) para los dos periodos. En el ensayo de resistencia al estallido del canal de vaciado de las bolsas abiertas, con las bolsas llenas de agua, cerradas y pegadas sobre una plancha lisa, después de aplicar cargas de compresión hasta el estallido del canal, los dos sistemas no mostraron diferencias significativas. En el ensayo de resistencia a la separación entre el disco y la bolsa, ensamblada cada bolsa a su disco correspondiente y aplicadas cargas de tracción hasta la separación, también hubo diferencias significativas a favor del Fabricante I (Coloplast).<br/>Conclusión: se puede afirmar que ambos sistemas son seguros, pero el sistema Coloplast presenta mayor durabilidad ante la degradación por el efluente y mayor coeficiente de seguridad frente a la separación entre la bolsa y el disco.
520 8# - SUMMARY, ETC.
Summary, etc. Objective: to compare the mechanical characteristics of the two-piece ostomy systems most widely used in Spain: (Coloplast or Manufacturer I and Manufacturer II), through mechanical tests.<br/>Method: tests were conducted in the Instituto de Biomecánica de Valencia (IBV), using a MTS INSIGHT/468 universal test machine, under environmental conditions of controlled temperature (22-24 ºC) and humidity (39-41%). The sample size for each test was 10 units per each type of system. Three tests were conducted: 1) Resistance test to degradation of the adhesive in saline solution; 2) Resistance test to burst of the outlet in open pouches; 3) Resistance test for the separation between the disc and the pouch.<br/>Results: in the test of resistance to degradation of the adhesive in saline solution, both adhesives were submitted to 6 and 12-hour degradation periods in saline solution at 37 ºC, and significant differences were presented in favour of Manufacturer 1 (Coloplast) for both time periods. In the resistance test for the burst of the outlet in open pouches, the pouches were filled with water, closed and stuck on a flat plate; after applying compression charges until the outlet burst, both systems did not show any significant differences. In the resistance test for the separation between disc and pouch, each pouch was assembled with its disc, and traction charges were applied until their separation; there were significant differences in favour of Manufacturer I (Coloplast).<br/>Conclusion: it can be stated that both systems are safe, but the Coloplast system shows higher durability in terms of degradation by effluent, and a higher safety coefficient regarding the separation between pouch and disc.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term estoma
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term ostomía
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term dispositivo de ostomía
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term tipo de estoma
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term entorno periestomal
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term calidad de vida
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term stoma
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term ostomy
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term ostomy device
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term type of stoma
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term peristomal setting
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term quality of life
773 ## - HOST ITEM ENTRY
Related parts -- 2020 v. 23, n.1, p.18-23
Title Metas de enfermería.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 26/07/2022   PP17 v23(1):18-23 26/07/2022 26/07/2022 Artículo de revista

Powered by Koha