Facultad de Enfermería y Fisioterapia Salus Infirmorum

Fiabilidad intra e interevaluador de un sensor inercial para el rango de movimiento de la rodilla en sujetos asintomáticos = (Record no. 14218)

MARC details
000 -LEADER
fixed length control field 03838nas a22003257a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220718130741.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2019 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0211-5638
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Fiabilidad intra e interevaluador de un sensor inercial para el rango de movimiento de la rodilla en sujetos asintomáticos =
Remainder of title Intra- and inter-reliability of an inertial sensor for knee range of motion in asymptomatic subjects /
Statement of responsibility, etc. H. Beltran-Alacreu, G. Navarro-Fernandez, J. San Juan-Burgueño, J.A. Gonzalez-Sanchez, S. Lerma-Lara, O. Rodriguez-Lopez, y D. Munoz-García
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.129-130
520 3# - SUMMARY, ETC.
Summary, etc. Introducción La cuantificación del rango de movimiento de la rodilla es una medida clínicamente relevante en el ámbito sanitario, ya que su disminución puede alterar las actividades de la vida diaria. La obtención de una medida fiable del rango de movimiento nos permite valorar la eficacia de las intervenciones, así como la gravedad de la enfermedad. Por esto, el objetivo de este estudio fue conocer la fiabilidad intra e interevaluador de un protocolo para el rango de movimiento articular de la rodilla llevado a cabo con un sensor inercial en sujetos asintomáticos.<br/><br/>Métodos Se midió el rango de movimiento de 32 rodillas en sujetos asintomáticos, se realizaron 2 sesiones de medición, una por evaluador, en el mismo día. En cada sesión se hicieron un total de 8 mediciones (2 medidas para flexión en decúbito supino, 2 medidas para extensión en decúbito supino, 2 medidas para flexión en bipedestación y 2 para la extensión en bipedestación).<br/><br/>Resultados Para la fiabilidad interevaluador se consiguieron buenos resultados con un ICC superior a 0,79 para todos los movimientos. Los datos obtenidos para la fiabilidad intraevaluador en todos los movimientos fueron excelentes (ICC > 0,88).<br/><br/>Conclusión Este estudio obtuvo una excelente fiabilidad interevaluador e intraevaluador para los sujetos sanos midiendo con sensores inerciales.
520 8# - SUMMARY, ETC.
Summary, etc. Introduction The quantification of knee range of motion is a clinically relevant measurement in the healthcare setting, as its decrease can alter activities of daily living. Collecting reliable measurements of the range of motion allows us to evaluate the reliability of interventions, or the severity of the pathology. The objective of this study was to obtain the intra- and inter- rater reliability of a protocol for the knee the range of joint motion, measured with an inertial sensor in asymptomatic subjects.<br/><br/>Methods The range of motion of 32 asymptomatic knees was measured. Two measurement sessions were performed by two different evaluators. A total of 8 measurements were made in each session: 2 measurements for flexion in supine decubitus position, 2 measurements for extension in supine decubitus, 2 measurements for flexion in standing position and 2 measurements for extension in standing position.<br/><br/>Results For inter-rater reliability, good results were achieved, with an ICC > 0.79 for all movements. The obtained data for intra-rater reliability in all the movements was excellent, with an ICC > 0.88.<br/><br/>Conclusion This study obtained excellent inter-rater and intra-rater reliability for healthy subjects.
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term fiabilidad test-retest
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term reproductibilidad de resultados
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term acelerometría
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term rango de movimiento
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term rodilla
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term test-retest reliability
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term reproducibility of results
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term accelerometry
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term range of motion
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term knee
773 ## - HOST ITEM ENTRY
Related parts -- 2019, v. 41, n. 3, p. 123-130
Title Fisioterapia
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 18/07/2022   PP11 v41(3):123-130 18/07/2022 18/07/2022 Artículo de revista

Powered by Koha