Facultad de Enfermería y Fisioterapia Salus Infirmorum

Estudio de la calidad de la medida de cargas ejercidas sobre bastones canadienses instrumentados = (Record no. 14010)

MARC details
000 -LEADER
fixed length control field 04817nas a22003257a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220624140338.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2011 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1135-8599
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Estudio de la calidad de la medida de cargas ejercidas sobre bastones canadienses instrumentados =
Remainder of title A study on the quality of the measurement of weight applied on implemented canadian crutches /
Statement of responsibility, etc. G. Chamorro-Moriana, J. Rebollo-Roldán, J.J. Jiménez-Rejano, A. García-Valenzuela, R. Chillón-Martínez, A. García-Delgado
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 160
520 3# - SUMMARY, ETC.
Summary, etc. Introducción: en la actualidad no hemos encontrado ningún sistema de medición de cargas adaptado a bastones canadienses, que sea factible en la práctica clínica diaria para conocer y corregir la fuerza aplicada por los pacientes sobre los mismos durante la marcha asistida. Objetivo: conocer la calidad de la medida de las cargas ejercidas sobre bastones canadienses que hemos instrumentado, como primer paso en la validación de un sistema, que hemos ideado, para la medición y el registro informatizado de tales cargas, cuando son ejercidas por los pacientes durante la marcha asistida. Material y método. Diseño: estudio experimental de la medida, y de concordancia. Variables: masa aplicada, mediciones efectuadas por los bastones, y errores en las mediciones. Muestra: nueve pesas calibradas de 5 a 45 kg. Intervalo de confianza 95 %. Resultados: el análisis de la fiabilidad mediante el coeficiente de correlación intraclase y el alfa de Cronbach, así como la correlación entre las variables medida verdadera y observada, aplicando el coeficiente Rho de Spearman y el de Pearson fueron de 1 (p < 0,001). El análisis de la varianza mostró un nivel de significación p > 0,05. El error promedio en las mediciones fue de 0,1097, ajustándose la variable error a la distribución normal (p > 0,05 en la prueba de Shapiro-Wilk). Discusión: el error, considerado azaroso, se tradujo en 110 gr, indicando unos niveles muy bajos del mismo, que oscilaban entre 62 y 167 gr. Por tanto, aceptamos que no hay diferencia entre la medida verdadera, las medidas observadas con el bastón derecho y con el bastón izquierdo. Conclusiones: los bastones canadienses que hemos instrumentado constituyen una herramienta fiable y válida para medir las cargas aplicadas por pesas calibradas. Es indiferente el empleo de uno u otro bastón, dado que no existen diferencias significativas entre sus mediciones.
520 8# - SUMMARY, ETC.
Summary, etc. Introduction: Currently we have not found any load measurement system adapted to Canadian canes, which is feasible in daily clinical practice to know and correct the force applied by patients on them during assisted walking. Objective: to know the quality of the measurement of the loads exerted on Canadian canes that we have instrumented, as a first step in the validation of a system that we have devised, for the measurement and computerized recording of such loads, when they are exerted by the patients. during assisted walking. Material and method. Design: experimental study of the measure, and concordance. Variables: applied mass, measurements made by the rods, and errors in the measurements. Sample: nine calibrated weights from 5 to 45 kg. Confidence interval 95%. Results: the reliability analysis using the intraclass correlation coefficient and Cronbach's alpha, as well as the correlation between the true and observed measured variables, applying the Spearman's Rho coefficient and Pearson's were 1 (p < 0.001). The analysis of variance showed a level of significance p > 0.05. The average error in the measurements was 0.1097, adjusting the error variable to the normal distribution (p > 0.05 in the Shapiro-Wilk test). Discussion: the error, considered random, was translated into 110 gr, indicating very low levels of it, which ranged between 62 and 167 gr. Therefore, we accept that there is no difference between the true measurement, the measurements observed with the right stick and with the left stick. Conclusions: the Canadian poles that we have instrumented constitute a reliable and valid tool to measure the loads applied by calibrated weights. The use of one or the other cane is indifferent, since there are no significant differences between their measurements.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term marcha
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term medición
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term validación
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term bastón
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term fisioterapia
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term gait
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term measurement
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term validation
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term crutch
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term physiotherapy
773 ## - HOST ITEM ENTRY
Related parts -- 2011 v.40, n.3, p 155-160
Title Cuestiones de fisioterapia
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 24/06/2022   PP6 v40(3):155-160 24/06/2022 24/06/2022 Artículo de revista Cajonera

Powered by Koha