Catéteres de silastic: localización del extremo distal mediante monitorización electrocardiográfica = (Record no. 13550)

MARC details
000 -LEADER
fixed length control field 03338nas a22002057a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20211118173842.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t1997 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0210-5020
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Catéteres de silastic: localización del extremo distal mediante monitorización electrocardiográfica =
Remainder of title Silastic catheters: pinpointing the end tip of the catheter by means of electrocardiographic monitoring /
Statement of responsibility, etc. Luisa Giraldo Lozano, María Barjau Capdevila
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 52
520 3# - SUMMARY, ETC.
Summary, etc. La colocación de catéteres centrales de silastic es una maniobra frecuente en las unidades de cuidados intensivos neonatales (UCIN) desde hace varios años. Pero esta técnica, como muchas otras, no está exenta de riesgos y complicaciones si se realiza incorrectamente.<br/>La mayoría de complicaciones que describe la literatura, como arritmias, perforaciones miocárdicas, trombosis, derrames pleurales, etc., están relacionadas con el emplazamiento del catéter y la posible migración del mismo dentro del vaso donde originariamente quedó ubicado.<br/>Hasta el momento la exploración habitual para localizar el extremo distal de dicho catéter es la radiografía simple, pero en muchas ocasiones resulta difícil visualizar exactamente donde queda emplazado.<br/>Esta dificultad es debida a su pequeño calibre que no admite todo el contraste que sería deseable; por tal motivo a menudo es necesario administrar un contraste radiopaco y repetir la radiografía para tener la seguridad de que realmente está donde habíamos pretendido dejarlo.<br/>Mediante la monitorización electrocardiográfica, la utilización de una llave de tres vías con electrodo y una solución de cloruro sódico al 5,85% es posible localizar el extremo distal del catéter, sin necesidad de practicar control radiológico, ni administrar solución de contraste.
520 8# - SUMMARY, ETC.
Summary, etc. The placement of silastic central catheters has been a frequent maneuver in neonatal intensive care units (NICU) for several years. But this technique, like many others, is not without risks and complications if performed incorrectly.<br/>Most of the complications described in the literature, such as arrhythmias, myocardial perforations, thrombosis, pleural effusions, etc., are related to the location of the catheter and the possible migration of the catheter into the vessel where it was originally located.<br/>So far the usual examination to locate the distal end of this catheter is the simple x-ray, but in many cases it is difficult to visualize exactly where it is located.<br/>This difficulty is due to its small caliber that does not admit all the contrast that would be desirable; for this reason it is often necessary to administer a radiopaque contrast and repeat the x-ray to be sure that it really is where we had intended to leave it.<br/>Through electrocardiographic monitoring, the use of a three-way key with electrode and a solution of sodium chloride 5.85% it is possible to locate the distal end of the catheter, without the need to practice radiological control, or administer contrast solution.<br/>
773 ## - HOST ITEM ENTRY
Related parts -- 1997 v.20, 230, p 50-52
Title Rol. Revista de Enfermería
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 18/11/2021   PP7 v20(230):50-52 18/11/2021 18/11/2021 Artículo de revista Cajonera

Powered by Koha