Implantación de marcapaso: intervención de enfermería = (Record no. 13465)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02325nas a22002057a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20210917124238.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 171219t1998 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | 0210-5020 |
040 ## - CATALOGING SOURCE | |
Transcribing agency | Salus Infirmorum |
245 00 - TITLE STATEMENT | |
Title | Implantación de marcapaso: intervención de enfermería = |
Remainder of title | The nurse´s role in pacemaker implants / |
Statement of responsibility, etc. | Cristina López Díaz |
500 ## - GENERAL NOTE | |
General note | Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliografía: p. 72 |
520 3# - SUMMARY, ETC. | |
Summary, etc. | Se profundiza en la intervención de enfermería cardiológica en la unidad de coronarias, donde tiene un rol importante en la resolución de urgencias médicas que comprometen seriamente la vida del paciente.<br/>El trabajo consta de una breve introducción, en la que se expone la fisiología de la estimulación cardiaca, continuando con las posibles indicaciones para una estimulación artificial. Se describe la técnica de implantación de los distintos tipos de marcapaso, donde la enfermera/o tiene una intervención en los cuidados y técnicas previas, en el momento de la colocación del marcapaso como ayudante del médico, y en el control posterior del buen funcionamiento o la detección de complicaciones aportando una resolución temprana a las mismas. Para ello sus conocimientos previos le aportarán seguridad de actuación en casos de urgencia. |
520 8# - SUMMARY, ETC. | |
Summary, etc. | The cardiology nursing intervention in the coronary unit is studied in depth, where it plays an important role in the resolution of medical emergencies that seriously compromise the life of the patient.<br/>The work consists of a brief introduction, in which the physiology of cardiac stimulation is exposed, continuing with the possible indications for artificial stimulation. The implantation technique of the different types of pacemaker is described, where the nurse has an intervention in the previous care and techniques, at the time of the placement of the pacemaker as a doctor's assistant, and in the subsequent control of the proper functioning or the detection of complications providing an early resolution to them. To do this, your prior knowledge will provide you with security of action in emergencies. |
773 ## - HOST ITEM ENTRY | |
Related parts | -- 1998 v.21, 234, p 67-72 |
Title | Rol. Revista de Enfermería |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Universal Decimal Classification |
Koha item type | Artículo de revista |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Home library | Current library | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type | Public note |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal Decimal Classification | Non-fiction | Revistas y artículos | Revistas y artículos | 17/09/2021 | PP7 | v21(234):67-72 | 17/09/2021 | 17/09/2021 | Artículo de revista | Cajonera |