Facultad de Enfermería y Fisioterapia Salus Infirmorum

Temperatura corporal: diferentes sistemas de medición = (Record no. 13385)

MARC details
000 -LEADER
fixed length control field 03242nas a22002057a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210712130444.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t1999 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0210-5020
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Temperatura corporal: diferentes sistemas de medición =
Remainder of title Body temperature: different ways to take it /
Statement of responsibility, etc. Blanca Marín Fernández, Juana Hermoso de Mendoza Cantón, Margarita Aliaga Marín, Edurne Berrade Zubiri, Concepción Brun Sandiumenge, Inés Aguinaga Ontoso, Francisco Guillén Grima
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 827
520 3# - SUMMARY, ETC.
Summary, etc. La medición de la temperatura corporal es una práctica habitual en enfermería, que tradicionalmente se realiza con el termómetro de barra de mercurio, aplicada a nivel axilar, oral o rectal. El desarrollo tecnológico supone que hoy en día dispongamos de una gran variedad de termómetros y lugares donde medir la temperatura. Con el objetivo de comparar las ventajas e inconvenientes, así como la fiabilidad, que presentan estos termómetros realizamos el presente estudio midiendo la temperatura timpánica y axilar a sujetos sanos.<br/>Por otro lado se estudia el grado de concordancia entre valores axilares y timpánicos con la temperatura corporal central medida en pacientes ingresados en Cuidados Intensivos y portadores de un catéter de Swan-Ganz. Los resultados obtenidos muestran que al comparar las temperaturas axilares con las timpánicas, son mayores las mediciones realizadas en el tímpano respecto a las de la axila, siendo esta diferencia menor en temperaturas altas. Respecto a la correlación entre temperatura axilar, timpánica y central realizada en pacientes ingresados en Cuidados Intensivos, se muestra que la temperatura más precisa es la timpánica que es una décima menor que la central.
520 8# - SUMMARY, ETC.
Summary, etc. The measurement of body temperature is a common practice in nursing, which is traditionally carried out with a mercury bar thermometer, applied at the axillary, oral or rectal level. Technological development means that today we have a wide variety of thermometers and places to measure temperature. In order to compare the advantages and disadvantages, as well as the reliability, of these thermometers, we carried out the present study by measuring the tympanic and axillary temperature in healthy subjects.<br/>On the other hand, the degree of concordance between axillary and tympanic values ​​with the central body temperature measured in patients admitted to Intensive Care and carriers of a Swan-Ganz catheter is studied. The results obtained show that when comparing axillary with tympanic temperatures, the measurements made on the eardrum are greater than those of the axilla, with this difference being less at high temperatures. Regarding the correlation between axillary, tympanic and central temperature performed in patients admitted to Intensive Care, it is shown that the most accurate temperature is the tympanic temperature, which is one tenth lower than the central temperature.
773 ## - HOST ITEM ENTRY
Related parts -- 1999 v.22, 12, p 823-827
Title Rol. Revista de Enfermería
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 12/07/2021   PP7 v22(12): 823-827 12/07/2021 12/07/2021 Artículo de revista Cajonera

Powered by Koha