MARC details
000 -LEADER |
fixed length control field |
04939nmi a22004457a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210519164729.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m||||| |||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
c| zz uauuu |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
180124d2020 sp ||||| |||| 00| 0 spa d |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
López Álvarez, Raquel |
9 (RLIN) |
3535 |
245 10 - TITLE STATEMENT |
Title |
Uso adecuado de los sistemas de monitorización intersticial de la glucosa / |
Statement of responsibility, etc. |
Raquel López Álvarez; tutor: Raúl Quintana Alonso |
Medium |
[Trabajo Fin de Grado] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Date of publication, distribution, etc. |
2020 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
1 archivo (pdf.) ; |
Dimensions |
683 KB |
500 ## - GENERAL NOTE |
General note |
Trabajo fin de grado. Defendido en 2020 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Introducción y objetivos: Los sistemas de monitorización intersticial de glucosa recogen los valores de glucosa intersticial del paciente a través de el sensor insertado en la piel del paciente. Estos se recogen en un dispositivo, el cual le permite al paciente hacer uso de él, cuándo y dónde quiera pudiendo realizar cambios según sean los resultados, sobre su alimentación, dosis de insulina o ejercicio físico. El objetivo general de este trabajo es describir los diferentes sistemas de monitorización para el control adecuado de la glucosa en los pacientes diagnosticados de diabetes mellitus.<br/>Material y método: Se ha realizado una revisión bibliográfica a través de búsquedas en las bases de datos Scielo, Pubmed y Lilacs. Para ello se han utilizado unos criterios de selección de artículos publicados en los últimos 10 años, escritos en Inglés y Español. Se han excluido aquellos artículos que hablasen de la influencia de medidas de nutrición y ejercicio en la diabetes <br/>mellitus.<br/>Resultados y Discusión: Se incluyeron 21 resultados. Los sistemas de monitorización presentan una satisfactoria disminución en los niveles de hemoglobina glicosilada en pacientes diagnosticados de diabetes mellitus, además de influir en los episodios hiperglucémicos e hipoglucémicos como en la variabilidad glucémica. Como consecuencia del uso de estos sistemas se <br/>producen cambios en la calidad de vida de los pacientes, relaciones conyugales y entorno familiar. <br/>Conclusión: Los sistemas de monitorización intersticial de glucosa reducen considerablemente los valores de hemoglobina glicosilada de pacientes diagnosticados de Diabetes Mellitus, disminuyendo u omitiendo el número de episodios hipoglucémicos. Mejoran la calidad de vida del paciente como de su entorno, reduciendo situaciones de estrés ocasionadas por el manejo de la <br/>enfermedad.<br/> |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Introduction and objectives: Interstitial glucose monitoring systems collect interstitial glucose values from the patient through the sensor inserted under the patient's skin. This data is collected in a device, and it is available from the paciente in anytime or anywhere. Patient adjust his diet the insulin dose or physical exercise based on this data. Main objective of this work is describing <br/>different monitoring systems for proper glucose control in patient’s diagnostic with diabetes mellitus.<br/>Material and method: A bibliographic review was performed through Scielo, Pubmed and Lilacs databases findings. For this purpose, it has been using articles published selection criteria have been used for articles published in the last ten years, written in English or Spanish. Articles related to the influence on nutrition influence and exercise measures have been excluded in this analysis.<br/>Results and discussion: 21 results were included. Monitoring systems show a satisfactory decrease in glycated haemoglobin levels in patients diagnosed with diabetes mellitus, in addition to influencing hyperglycaemia and hypoglycaemia episodes, as well as blood glucose variability. Results These monitoring systems reviews changes in the quality of life of patients, marital relationships, and family environment.<br/>Conclusion: Interstitial glucose monitoring systems considerably reduce glycated haemoglobin values in patients diagnosed with Diabetes Mellitus, by reducing or removing the number of hypoglycaemia episodes. This improves the quality of life of the patient and their environment, reducing stress situations caused by the management of the disease |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
diabetes mellitus |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
monitoreo |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
impacto en la salud |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
dispositivos |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
glucemia |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
insulina |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
hemoglobina A glucada |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
índice glucémico |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
hipoglucemia |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
diabetes mellitus |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
monitoring |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
impacts on health |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
equipment and supplies |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
blood glucose |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
insulin |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
glycated hemoglobin A |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
glycemic index |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
hypoglycemia |
700 1# - ADDED ENTRY--PERSONAL NAME |
Personal name |
Quintana Alonso, Raúl |
9 (RLIN) |
3029 |
710 2# - ADDED ENTRY--CORPORATE NAME |
Corporate name or jurisdiction name as entry element |
Universidad Pontificia de Salamanca. |
Subordinate unit |
Facultad de Enfermería y Fisioterapia Salus Infirmorum. |
-- |
Grado en Enfermería. |
9 (RLIN) |
489 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
TFG/TFM |