MARC details
000 -LEADER |
fixed length control field |
02677nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210325122135.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2005 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1575-4146 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Estudios electrofisiológicos con sistemas de navegación = |
Remainder of title |
Electrophysiological studies with navigation systems / |
Statement of responsibility, etc. |
Izquierdo Torre MV |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p. 44 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
El Estudio Electrofisiológico cardíaco (EEF) tradicionalmente se realiza con registros endocavitarios. Estos se consiguen a través de la introducción de varios catéteres colocados por fluoroscopia en distintas zonas delcorazón.<br/>Con los sistemas de navegación se reduce casi totalmente el tiempo de radioscopia. Se visualiza en 3D la cámara cardíaca a estudio, moviéndose por ella en tiempo real. Hay varios sistemas: EnSite NavX y EnSite Array (St. Jude Medical), LocaLisa (Medtronic), Carto (Biosense Webster). El primer registro de un estudio electrofisiológico fue en 1971 y hasta la fecha ha tenido una importante evolución siendo lo último la aparición de los sistemas de navegación mencionados, que suponen un gran avance. Para enfermería la mayor dificultad va en relación directa con la cámara a investigar. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Electrophysiological studies have been performed traditionally by means of endocavitary registers, through inserting several catheters guided by fuoroscopy and placing them in different areas of the heart. The navigation systems have reduced almost completely the radioscopy time. The cardiac chamber investigated is visualized in 3-D, moving around it in real time.<br/>There are several stystems: EnSite NavX and EnSite Array (St. Jude Medical), LocaLisa (Medtronic), Carto (Biosense Webster).The first electrophysiological study was recorded in 1971, and up to date, the development in this field has increased hugely, becoming the most innovative the navigation systems mentioned previously, which involve a great advance. Regarding to nursing, the biggest problem is connected directly to the chamber researched. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
sistema de navegación por catéter |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
estudio electrofisiológico |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
registros endocavitarios |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
catéter mapping system |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
electrophysiology study |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
endocavitary registers |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2005, v. 12, n. 36, p. 40-44 |
Title |
Enfermería en Cardiología |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/3606.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/3606.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |