Facultad de Enfermería y Fisioterapia Salus Infirmorum

Caso clínico: seguimiento de marcapasos complicado = (Record no. 12741)

MARC details
000 -LEADER
fixed length control field 03062nas a22002537a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210325124756.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2007 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Caso clínico: seguimiento de marcapasos complicado =
Remainder of title Pacemaker follow-up complicated /
Statement of responsibility, etc. Ramírez, P. ; Alonso, G. ; Aguado, E. ; Herrera, A. Pérez, PP.
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
520 3# - SUMMARY, ETC.
Summary, etc. Presentamos el caso de un paciente joven de 27 años de edad que fue sometido a una miectomía septal a los 12 años, tras la cual desarrolla un bloqueo AV completo intermitente. Se implantó un generador y sistema doble cámara en hemitórax izquierdo. A los 15 años, el electrodo auricular presentaba una impedancia anormal (>9999 ohms) y detección de ruido, por fractura del mismo. Se dejó el marcapasos programado en modo VVI ya que no era dependiente del mismo. Un año después, el electrodo ventricular muestra también datos anormales, y se decide explantar todo el sistema. Se implantan nuevo generador y electrodos en aurícula y ventrículo derechos. Dos años después, el electrodo auricular muestra de nuevo fallos de detección y alta impedancia, posiblemente por crecimiento del paciente y actividad física. Se extrae el electrodo auricular y se implanta nuevo electrodo por vía subclavicular derecha, tunelizándose hasta el lado izquierdo. Dos años después, el paciente permanece asintomático y sin datos de disfunción de los electrodos como del generador.
520 8# - SUMMARY, ETC.
Summary, etc. We present the case of a 27-years-old boy submitted to a septal myectomy at the age of 12. After the procedure, the patient developed an intermittent complete AV-block, and a dual-chamber pacemaker was implanted in the left hemi thorax. At the age of 15, the atrial coil showed a dysfunction, with high impedance (>9999 ohms) and noise sensing because of lead fracture. The pacemaker was programmed to VVI mode because the patient was not pacemaker dependent. One year later, the ventricular coil failed too, and all the system (leads and pulsegenerator) was explanted. A new device and leads were implanted and the pacemaker was programmed in DDD mode. Two years later, the atrial lead showed again an abnormal sensing and high impedance because of fracture, probably due to the growing of the patient and physical activity. The atrial lead was explanted and a new coil was inserted via right subclavia vein and then tunnelized to the left side, where the pacemaker was implanted. Two years later, the patient remains asymptomatic and the pacemaker and leads are in optimal conditions
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term marcapasos
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term seguimiento de complicaciones
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term pacemaker
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term follow up complicated
773 ## - HOST ITEM ENTRY
Related parts -- 2007, v. 14, n. 41, p. 60-62
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/4108.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/4108.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 24/01/2020   PP15 14(41):60-62 24/01/2020 24/01/2020 Artículo de revista Cajonera

Powered by Koha