Facultad de Enfermería y Fisioterapia Salus Infirmorum

Control de calidad en los cuidados de enfermería en el post-cateterismo cardiaco = (Record no. 12702)

MARC details
000 -LEADER
fixed length control field 05040nas a22003857a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210325134926.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2009 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Control de calidad en los cuidados de enfermería en el post-cateterismo cardiaco =
Remainder of title Quality control in post-cardiac catheterization nursing care /
Statement of responsibility, etc. Garcimartín P, Maull E, González P, Páez M*, Creus F, Sánchez D*, Bartolomé Y, Simó M
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.35
520 3# - SUMMARY, ETC.
Summary, etc. • Introducción: Un control de calidad post-cateterismo responde a la continuidad en los cuidados de enfermería, permitiendo identificar las complicaciones. • Material y métodos: Estudio prospectivo con inclusión de todos los enfermos sometidos a cateterismo ingresados, al menos, 24 horas. Clasificación según tipo de procedimiento, acceso vascular y método de hemostasia. Definición de las complicaciones como inmediatas, <3 horas, o tardías, >3 horas tras la finalización. Complicaciones mayores: hematoma >6 cm, sangrado con necesidad de transfusión y pseudoaneurisma. Menores: hematoma <6 cm y rezumo del punto de punción. Registro del cumplimiento con las recomendaciones sobre tiempos de retirada del compresivo y movilización. • Resultados: 829 enfermos, 457 (55,1%) con cateterismo diagnóstico y 372 (44,6%) con terapéutico. Acceso vascular: radial en 427 (51,5%), femoral en 395 (47,6%) y humeral en 7 (0,8%). A 220 enfermos (26,6%) se les colocó dispositivo de cierre, a 351 (42,3%) pulsera neumática y a 251 (30%) compresivo. Complicaciones inmediatas: 45 enfermos (5,5%), sangrado en el 3,5% y hematoma en el 1,9%. La punción radial se relacionó con menos complicaciones inmediatas (2,6% vs 8,9%, p<0,05). Complicaciones tardías: 135 enfermos (16,3%), sangrado en 109 (13,2%), hematoma en 19 (2,3%), pseudoaneurisma en 7 (0,8%). Todas menores. Se observó retraso en la retirada del compresivo o pulsera y la movilización cuando la recomendación fue <12h (p<0,05). • Conclusión: El control de calidad permite registrar las complicaciones, según vía de acceso y método de hemostasia utilizado, y el cumplimiento de las recomendaciones. Debería conllevar modificaciones que comporten una mejora en la atención al enfermo.
520 8# - SUMMARY, ETC.
Summary, etc. • Introduction: Quality control after cardiac catheterization is part of the continuity of nursing care, enabling the identification of complications. • Material and Methods: Prospective study of all catheterized patients hospitalized during at least 24 hours; clasMaterial and Methods: Prospective study of all catheterized patients hospitalized during at least 24 hours; classified according to type of procedure, vascular access and haemostatic method. Definitions: early complications, <3h after procedure; late complications, >3h. Major complications: haematoma >6cm, bleeding requiring blood transfusion and pseudo aneurysm. Minor complications: haematoma <6cm, bleeding without the need for transfusion, unsealed puncture site. Register of compliance with recommendations on artery compress withdrawal and patient mobilization times. • Results: Total 829 patients. 457 (55.1%) after coronary angiography and 372 (44.6%) after percutaneous coronary intervention. Vascular access: radial artery in 427 (51.5%), femoral artery in 395 (47.6) and humeral artery in 7 (0.8%). Haemostatic method: percutaneous closure device in 226 (26.6%), haemostatic wristlet in 351 (42.3%) and compress in 251 (30%). Early complications: 45 patients (5.5%). bleeding (3.5%) and haematoma <6cm (1.9%). Radial access was associated with fewer early complications (2.6 vs 8.9%; p<0.05). Late complications, all minor: 135 patients (16.3%), bleeding in 109 (13.2%), haematoma in 19 (2.3%), and pseudo aneurysm in 7 (0.8%). There was a delay in haemostatic method withdrawal and patient mobilization times as compared with the recommendation of <12 h (p<0.05). • Conclusions: Quality control allows registration of complications, according to access route and the haemostatic method used, as well as compliance with the recommendations. This should lead to improvements in patient care.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term angiografía coronaria
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term angioplastia coronaria transluminal percutánea
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term arteria femoral
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term arteria radial
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term complicaciones
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemostasis
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term registros de enfermería
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term coronary angiography
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term transluminal percutaneous coronary angioplasty
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term femoral artery
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term radial artery
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term complications
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term haemostasis
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term nursing registers
773 ## - HOST ITEM ENTRY
Related parts -- 2009, v. 16, n. 46, p. 30-35
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/4605.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/4605.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 22/01/2020   PP15 16(46):30-35 22/01/2020 22/01/2020 Artículo de revista Cajonera

Powered by Koha