Caso clínico: rotura del aislante del electrodo de un marcapasos = (Record no. 12700)

MARC details
000 -LEADER
fixed length control field 04089nas a22003377a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210325135007.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2009 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Caso clínico: rotura del aislante del electrodo de un marcapasos =
Remainder of title Rupture of the pacemaker electrode insulation /
Statement of responsibility, etc. Aguirre Montoya C, Carmona Heredia A, Pinedo Iguíñez M
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.25
520 3# - SUMMARY, ETC.
Summary, etc. • Introducción: Presentamos el caso clínico de un paciente de 74 años al que se implantó un marcapasos VDD y en dos años se rompió el aislante del electrodo siendo detectado y seguido por enfermería. • Objetivo: Documentar que la disminución de la impedancia del electrodo corresponde al deterioro o rotura del aislante, en nuestro caso por cizallamiento clavicular. • Caso clínico: El marcapasos se implantó en el paciente por bloqueo atrio-ventricular completo y síncopes. A los catorce meses del implante se detectó una bajada de 400 ohmios con umbral y RX de tórax normales; a los veintiséis meses la impedancia bajó de 300 ohmios y el paciente presentó estimulación pectoral intermitente, se decidió recambio completo de todo el sistema de estimulación. En la RX de comprobación post reimplante se evidenció la rotura del aislante en la zona donde se cruzan la clavícula y la primera costilla. El paciente estuvo informado en todo momento, dando lugar a que éste expresara sus temores y preocupaciones. Mediante escucha activa y con respuestas concretas, enfermería le ayudó a afrontar la situación ofreciéndole seguridad. • Discusión: La impedancia del electrodo baja cuando se rompe el aislante, en nuestro caso, por cizallamiento clavicular. La programación en monopolar es interesante. Las roturas de los electrodos son poco frecuentes y son mayoría en los implantes por subclavia. La atención de enfermería es muy importante para el enfermo y familia.
520 8# - SUMMARY, ETC.
Summary, etc. • Introduction: We report the case of a 74- year-old patient with a VDD pacemaker implanted two years before: rupture of the electrode insulation was detected and followed by nursing staff. • Objective: To report that decreased electrode impedance corresponds to deterioration or rupture of the insulation, in our case due to clavicular shearing. • Case report: The pacemaker was implanted because of complete atrioventicular block and syncope. Fourteen months after implantation, a decrease of 400 ohms was detected, with normal threshold and chest X-ray; after twenty six months the impedance was lower than 300 ohms and the patient showed intermittent pectoral stimulation; it was decided to change the whole stimulation system. In the post re-implantation X-ray, the insulation rupture was observed in the area where the clavicle and the first rib intersect. The patient was kept informed at all times, which allowed him to express his fears and worries. Through listening closely and giving clear answers, nursing staff were able to help him face the situation while offering assurance. Discussion: Electrode impedance decreases when the insulation ruptures, in our case caused by clavicular shearing. The programming in monopolar devices is interesting. Electrodes ruptures are rare and mostly caused by subclavian implantation. The attention given by nursing staff is very important in helping both the patient and the family through times of stress.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term marcapasos
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term enfermería
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term rotura aislante
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term impedancia electrodo
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term complicaciones
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term pacemaker
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term nursing staff
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term insulation rupture
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term electrode impedance
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term complications
773 ## - HOST ITEM ENTRY
Related parts -- 2009, v. 16, n. 46, p. 23-25
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/4603.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/4603.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 22/01/2020   PP15 16(46):23-25 22/01/2020 22/01/2020 Artículo de revista Cajonera

Powered by Koha