Facultad de Enfermería y Fisioterapia Salus Infirmorum

¿Es correcta la extracción de muestras sanguíneas para determinación del tiempo de cefalina desde el circuito de depuración extrarrenal continua? Comparación de dos métodos de extracción = (Record no. 12696)

MARC details
000 -LEADER
fixed length control field 05018nas a22003617a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210325135114.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2009 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title ¿Es correcta la extracción de muestras sanguíneas para determinación del tiempo de cefalina desde el circuito de depuración extrarrenal continua? Comparación de dos métodos de extracción =<br/>
Remainder of title Is it right the extraction of samples blood for determination of time cephalin from the circuit of purification extrarenal continuous? Comparison of two methods of extraction /
Statement of responsibility, etc. Gómez Palomar, MJ, Tamayo Alediño, R
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.106-107
520 3# - SUMMARY, ETC.
Summary, etc. • Objetivo: Demostrar la fiabilidad de un método para la determinación del tiempo de cefalina en pacientes sometidos a hemodiafiltración continua (CVVHDF) y minimizar molestias al paciente, su anemización progresiva y optimizar el rendimiento de enfermería. • Método: 163 pares de determinaciones simultáneas de tiempo de cefalina, mediante extracción venosa directa o arterial por catéter no heparinizado versus punción en toma proximal de la línea aferente del circuito extracorpóreo de la diálisis. • Variables: unidad de control, dosis de heparina administrada, horas de funcionando del circuito hasta la extracción y pares de valores de cefalina. • Análisis estadístico: porcentajes, t-de Student para datos pareados y Chi-cuadrado para variables cualitativas. Programa informático: SPSS versión 15. • Resultados: 163 pares de determinaciones. El 93,2% con perfusión de heparina en el circuito: dosis media de 173,8±81 (60-380) La media de funcionamiento del circuito hasta la extracción resultó de 22,97±19 (1-72) tStudent mostró alta correlación entre los pares de datos (0,975) y significación estadística de 0,0001. Error típico 0,015. No hay significación estadística para la diferencia de los pares de resultados según las horas de uso del circuito, sí entre la unidad de control BMS y Prisma (0,01) y las diferentes dosis de heparina (0,001) • Conclusiones: las determinaciones analíticas, incluido el tiempo de cefalina mediante extracción por punción de la primera toma de la línea aferente del circuito de CVVHDF es correcta y totalmente fiable. Destaca el ahorro de sangre (no es necesario desechar volumen previo alguno), de molestias al paciente (no se entra en contacto con él) y el tiempo de enfermería (menor de 30 segundos)
520 8# - SUMMARY, ETC.
Summary, etc. • Objective: To demonstrate the reliability of a method for determining the cephalin time in patients undergoing continuous hemodiafiltration (CVVHDF) and minimize discomfort to the patient, progressive anaemia and optimize the time to nursing. • Method: 163 pairs of simultaneous determinations of cephalin time, through direct venous extraction or arterial catheter nonheparinised versus puncture takes proximal afferent line of the extracorporeal circuit of dialysis. • Variables: control console, dose of heparin infused, hours of operation of the circuit until the extraction and value pairs of cephalin. • Statistical analysis: percentages, t-Student’s test for paired data and chi-square for qualitative variables. Software: SPSS version 15. • Results: 163 pairs of determinations. 93.2% had heparin in the circuit: average dose of 173.8 ± 81 (60-380) Mean performance of the circuit until the extraction was of 22.97 ± 19 (1-72) t-Student showed high correlation between pairs of data (0.975) and statistical significance of 0.0001. Standard error 0.015. No statistical significance for the difference of the pairs of results by the hours of use the circuit, it was found between the BMS control unit and Prisma (0.01) and different doses of heparin (0.001) • Conclusions: the analytical determinations, including the time of cephalin by extraction by puncturing the first shot of the line afferent CVVHDF circuit is accurate and totally reliable. Stresses blood saving (no need to discard any previous volume), the absence of discomfort for patient (no contact with him) and time savings for nursing (they need less than 30 seconds)
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term método de toma de muestras sanguíneas
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term heparina sódica
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term tiempo de cefalina
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemodiafiltración venovenosa continua
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term CVVHDF
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term técnicas de reemplazo renal continuo
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term method of blood sampling
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term heparin sodium
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term time cefalina
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemodiafiltyración venovenosa continuous
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term CVVHDF
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term continuous renal replacement techniques
773 ## - HOST ITEM ENTRY
Related parts -- 2009, v. 16, n. 47-48, p. 104-107
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/47_48_20.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/47_48_20.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 22/01/2020   PP15 16(47-48):104-107 22/01/2020 22/01/2020 Artículo de revista Cajonera

Powered by Koha