Facultad de Enfermería y Fisioterapia Salus Infirmorum

Implante percutáneo de prótesis valvular aórtica = (Record no. 12674)

MARC details
000 -LEADER
fixed length control field 04661nas a22003137a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210325170148.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2010 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Implante percutáneo de prótesis valvular aórtica =
Remainder of title Percutaneous implantation of aortic valvular prothesis /
Statement of responsibility, etc. Méndez Rubio J, Gil Pérez R*, Millán Vázquez FJ, Macias Pérez I, De Prada Otermin G, Carrasco Ruiz R, Duarte Arlandi M
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.56
520 3# - SUMMARY, ETC.
Summary, etc. • Introducción: Debido al envejecimiento de la población, la estenosis aórtica severa sintomática es una patología cada vez más prevalente y aunque el tratamiento de elección es la cirugía suelen, estos pacientes de edad muy avanzada, presentar comorbilidad asociada que incrementa el riesgo quirúrgico. • Objetivos: Presentar resultados de nuestra experiencia y describir protocolo de actuación. • Material y Método: Entre abril de 08 y enero de 09 se realizó implante percutáneo de prótesis aórtica Corevalve en 29 pacientes. Los criterios de selección fueron clínicos y anatómicos (diámetros del plano valvular y vía de acceso iliofemoral). En 27 pacientes la vía de acceso elegida fue femoral derecha o izquierda y en 2 casos el acceso se realizó por subclavia izquierda, mediante presentación y cierre quirúrgico. En los casos realizados por vía femoral el acceso fue percutáneo con 18F y el cierre con sutura arterial Prostar. Los implantes se realizaron bajo sedación del paciente y con anestesia local. Precisaron implante de marcapasos transcutáneo. • Resultados: N=29. La edad media fue de 77 años [50-92], 12 hombres y 19 mujeres. Las complicaciones relacionadas con la punción fueron: un fallo en el cierre Prostar y un caso de fuga de arteria iliaca, ambas precisaron cirugía vascular. Un infarto periprocedimiento por disección de arteria mamaria, precisó ser tratada con ACTP y stent. Un 40% presentó bloqueo A-V, precisando marcapasos transcutáneo. No hubo, en ningún caso, problemas de implante (migración u obstrucción coronaria). • Conclusiones: La implantación percutanea de la válvula aortica podría ser una alternativa en pacientes con estenosis aórtica severa con alto riesgo quirúrgico.
520 8# - SUMMARY, ETC.
Summary, etc. Due to the progressive aging of the population, the symptomatic severe aortic stenosis is a pathology that has an increased prevalence in our environement. Although the election treatment is surgery, these very elderly patients present associated co-morbidity which may increase the surgical risk. We present results of our experience and describe our own care protocol. Between 2008 April of and 2009 January, we made percutaneous implantation of aortic prosthesis (Corevalver ®) in 29 patients. The selection criteria were clinical and anatomical (diameters of the plane to valvular and iliofemoral access way). In 27 patients the chosen access was femoral arteria and in 2 cases the access was made through left subclavia. In the cases made by femoral route the access was percutaneous with 18F and sutured with arterial suture Prostar. The patients were under sedation and local anaesthesia. All the patients needed implants for a transcutaneous pacemaker. The mean age was of 77 years [50-92], 12 patients were men and 17 women. The complications related to the puncture were: failure in the Prostar closing and a flight of iliac artery; both needed vascular surgery. A hearth attack within the procedure, caused by a dissection of mammary artery, needed treatment with ACTP and stent. A 40% showed AV blockage, needing transcutáneo pacemaker. It did not have, in any case, problems of implants (migration or coronary obstruction). The aortic valve percutaneous implantation could be a very useful alternative in patients which were rejected for surgery due an elevated risk of death or adverse effects, providing them a solution for their health problem. Actually, this procedure is easy and cost effective.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemodinámica
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term estenosis aortica severa
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term válvula aortica autoexpandible
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term cateterismo cardiaco
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemodynamic
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term aortic severe stenosis
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term aortic valve self expanding
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term cardiac catheterization
773 ## - HOST ITEM ENTRY
Related parts -- 2010, v. 17, n. 49, p. 53-56
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/49_07.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/49_07.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 22/01/2020   PP15 17(49):53-56 22/01/2020 22/01/2020 Artículo de revista Cajonera