MARC details
000 -LEADER |
fixed length control field |
04611nas a22003377a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210325172436.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t20102011sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1575-4146 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Detección precoz de disfunción de electrodos mediante el sistema de monitorización remota = |
Remainder of title |
Early detection of electrodes dysfunction through the remote monitoring system / |
Statement of responsibility, etc. |
Burgos Mora J, González Molinillo I, Dávila Berrocal AR |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.62 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
• Introducción. El seguimiento domiciliario de los dispositivos implantables, ha mejorado los márgenes de seguridad, permitiendo la detección precoz de disfunciones y en muchos casos, evitando posibles complicaciones para el paciente. Los profesionales de enfermería, cada vez más, han asumido la revisión de los sistemas de monitorización. Presentamos dos casos en los que un diagnóstico temprano de problemas en el electrodo, ha evitado tratamientos inadecuados por parte del desfibrilador. CASO 1: Paciente con un desfibrilador implantado con capacidad de tele monitorización, que gracias a un algoritmo de alarma de impedancia, percibió una señal acústica por parte del desfibrilador y realizó una trasmisión, desde su domicilio, que nos permitió detectar signos de fractura del electrodo. El enfermero encargado de las revisiones, analizó los datos de la trasmisión y diagnosticó posible fractura del electrodo. Tras comunicarlo al equipo médico, se procedió al ingreso hospitalario y cambio del electrodo. CASO 2: Paciente con un desfibrilador implantado con capacidad de tele monitorización, que en una trasmisión periódica se observa sobredetección de campo lejano auricular y por tanto, doble cuenta del sistema. El enfermero responsable de las revisiones, después de analizar los datos de la trasmisión, diagnosticó la sobredetección e informó al equipo médico. Se procedió a la visita presencial del paciente, revisión del dispositivo y programación de una menor sensibilidad con lo que se evitaron posibles terapias inadecuadas del desfibrilador. • Conclusiones: La monitorización remota aumenta los niveles de seguridad de los dispositivos implantables permitiendo la detección precoz de disfunciones del sistema. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
• Introduction. The use of current available remote monitoring technologies for implantable devices has improved safety margins, allowing an early diagnosis of device- related malfunction that could in many cases, prevent from potential complications for the patients. Nurses have increasingly assumed the review of monitoring systems. We present two cases in which an early diagnosis of electrode disorders, avoided inappropriate therapies by the defibrillator. CASE 1: Patient with an ICD with telemonitoring capabilities, who perceived an acoustic signal due to an impedance alarm algorithm programmed previously, then decided to perform a transmission from his residence, which allowed us to detect signs of lead failure. The nurse in charge of the reviews, analyzed these data and diagnosed of suspected lead fracture. After informing the team physician, we proceed to hospital admission of the patient and lead replacement. CASE 2: Patient with implanted defibrillator with telemonitoring capability, in which in a periodic transmission it is observed far-field auricular oversensing and, therefore, double-counted system. The nurse in charge of the reviews, after analyzing all the transmission’s data, diagnosed the oversensing and informed the medical crew. We proceeded to the in-hospital visit of the patient, exam of the device and programmed a lower sensibility on the atrial lead, which avoided device inappropriate therapies. • Conclusions. Remote monitoring systems increase safety levels of implantable devices, allowing early detection of system- related dysfunctions. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
monitorización remota |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
detección precoz |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
rotura electrodo |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
sobredetección campo lejano |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
disfunción electrodo |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
remote monitoring |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
early detection |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
electrode failure |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
far field oversensing |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
electrode dysfunction |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2010-2011, v. 17-18, n. 51-52, p. 58-62 |
Title |
Enfermería en Cardiología |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/51_52_07.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/51_52_07.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |