MARC details
000 -LEADER |
fixed length control field |
05138nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326092925.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2015 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1575-4146 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Uso de la guía de presión en un laboratorio de hemodinámica = |
Remainder of title |
Use of the pressure guide wire in a cath-lab / |
Statement of responsibility, etc. |
Carlos Vázquez Cutillas, Laura Beneyto Armengot, Natalia Torres Cruzado, María José Morán Muñoz, Sandra Miralles Arqués, Ramón López-Palop, Araceli Frutos García, Pilar Carrillo Sáez, Alberto Cordero Fort, Pilar Agudo Quílez |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.51 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
• Introducción: La decisión de revascularización coronaria se basa principalmente en la imagen angiográfica y la clínica<br/>del paciente. En ocasiones estos datos son insuficientes para decidir el tratamiento de una lesión. La guía intracoronaria<br/>de presión permite conocer, en el laboratorio de hemodinámica, la repercusión funcional de una lesión pudiendo tomar<br/>decisiones in situ sin aplazamientos ni nuevas cateterizaciones. El objetivo de este estudio es presentar los resultados de la<br/>integración del empleo de la guía intracoronaria de presión en la práctica habitual de un laboratorio de hemodinámica.<br/>• Métodos: Estudio observacional unicéntrico, que incluye consecutivamente todos los pacientes con estenosis coronarias<br/>angiográficamente moderadas (estenosis visual por diámetro entre 40-70%) estudiadas mediante guía de presión entre el 1<br/>de enero de 2006 y el 31 de mayo de 2011.<br/>• Resultados: Se estudiaron 784 lesiones en 683 pacientes. Edad media: 68,03±10,6 años; 72,2% varones, 74,7% hipertensión,<br/>54,3% dislipemia, 40,3% diabetes, 47,6% de tabaquismo y 21,7% de infarto antiguo. La indicación de coronariografía fue:<br/>59,2% SCASEST; 24,9% angina estable; 7,6% SCACEST; 6,1% otra. Vaso estudiado: 57,4% descendente anterior; 21%<br/>coronaria derecha; 19,8% circunfleja; 1,8% otros. Se observó una RFF>0,75 en 602 (76,3%) de las lesiones estudiadas<br/>(528 pacientes, 77,3%). No se realizó angioplastia en alguna de las lesiones estudiadas en el 70,1% de los pacientes. No se<br/>observaron complicaciones graves asociadas al uso de la guía de presión.<br/>• Conclusiones: La integración de la guía intracoronaria de presión en la práctica clínica habitual es factible y segura. La<br/>valoración funcional de lesiones moderadas mediante guía intracoronaria permite evitar el intervencionismo coronario en más<br/>del 70% de las lesiones estudiadas |
520 8# - SUMMARY, ETC. |
Summary, etc. |
• Introduction: The decision to perform a coronary revascularization is mainly based on angiographic imaging and on the<br/>patient’s clinical condition. Sometimes, these data are insufficient to decide on the treatment of a lesion. The intracoronary<br/>USO DE LA GUÍA DE PRESIÓN<br/>EN UN LABORATORIO DE<br/>HEMODINÁMICA<br/>Pág. 48/ Enfermería en Cardiología. 2015; Año XXII (65) ARTÍCULOS CIENTÍFICOS<br/>pressure guide wire allows to ascertain, at the cath-lab, the functional repercussions of a lesion, it being thereby possible to<br/>make decisions in situ without further delays or new catheterizations. The aim of this study is to present the results of the<br/>incorporation of the use of intracoronary pressure guide wires into a cath-lab usual practice.<br/>Methods: Unicentric observational study including consecutively all patients with angiographically-moderate coronary stenoses<br/>(visual stenosis as per diameter between 40-70%) studied with the use of a pressure guide wire between 01-01-2006 and<br/>05-31-2011.<br/>• Results: 784 lesions were studied in 683 patients. Average age: 68.03 ± 10.6 years; 72.2% were male, 74.7% had hypertension,<br/>54.3% had dyslipidemia, 40.3% had diabetes, 47.6% were smokers and 21.7% had suffered from an old infarction. The<br/>indication for coronariography was: 59.2% NSTEMI, 24.9% stable angina, 7.6% STEMI, 6.1% other. Studied vessels: 57.4%<br/>anterior descending artery, 21% right coronary artery, 19.8% circumflex artery, 1.8% others. FFR > 0.75 was observed in 602<br/>(76.3%) of the lesions studied (528 patients, 77.3%) . No angioplasty was performed in some of the lesions studied in 70.1%<br/>of patients. No serious complication associated with the use of the pressure guide wire was observed.<br/>• Conclusions: The incorporation of the intracoronary pressure guide wire into the current clinical practice is feasible and safe.<br/>Functional assessment of moderate lesions with an intracoronary guide wire allows to avoid coronary interventionism in more<br/>than 70% of the lesions studied. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
angioplastia |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
revascularización miocárdica |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
circulación coronaria |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
angioplasty |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
myocardial revascularization |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
coronary circulation |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2015, v. 22, n. 65, p. 47-51 |
Title |
Enfermería en Cardiología |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/65_05.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/65_05.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |