Facultad de Enfermería y Fisioterapia Salus Infirmorum

Uso de la guía de presión en un laboratorio de hemodinámica = (Record no. 12597)

MARC details
000 -LEADER
fixed length control field 05138nas a22002897a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210326092925.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2015 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1575-4146
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Uso de la guía de presión en un laboratorio de hemodinámica =
Remainder of title Use of the pressure guide wire in a cath-lab /
Statement of responsibility, etc. Carlos Vázquez Cutillas, Laura Beneyto Armengot, Natalia Torres Cruzado, María José Morán Muñoz, Sandra Miralles Arqués, Ramón López-Palop, Araceli Frutos García, Pilar Carrillo Sáez, Alberto Cordero Fort, Pilar Agudo Quílez
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.51
520 3# - SUMMARY, ETC.
Summary, etc. • Introducción: La decisión de revascularización coronaria se basa principalmente en la imagen angiográfica y la clínica<br/>del paciente. En ocasiones estos datos son insuficientes para decidir el tratamiento de una lesión. La guía intracoronaria<br/>de presión permite conocer, en el laboratorio de hemodinámica, la repercusión funcional de una lesión pudiendo tomar<br/>decisiones in situ sin aplazamientos ni nuevas cateterizaciones. El objetivo de este estudio es presentar los resultados de la<br/>integración del empleo de la guía intracoronaria de presión en la práctica habitual de un laboratorio de hemodinámica.<br/>• Métodos: Estudio observacional unicéntrico, que incluye consecutivamente todos los pacientes con estenosis coronarias<br/>angiográficamente moderadas (estenosis visual por diámetro entre 40-70%) estudiadas mediante guía de presión entre el 1<br/>de enero de 2006 y el 31 de mayo de 2011.<br/>• Resultados: Se estudiaron 784 lesiones en 683 pacientes. Edad media: 68,03±10,6 años; 72,2% varones, 74,7% hipertensión,<br/>54,3% dislipemia, 40,3% diabetes, 47,6% de tabaquismo y 21,7% de infarto antiguo. La indicación de coronariografía fue:<br/>59,2% SCASEST; 24,9% angina estable; 7,6% SCACEST; 6,1% otra. Vaso estudiado: 57,4% descendente anterior; 21%<br/>coronaria derecha; 19,8% circunfleja; 1,8% otros. Se observó una RFF>0,75 en 602 (76,3%) de las lesiones estudiadas<br/>(528 pacientes, 77,3%). No se realizó angioplastia en alguna de las lesiones estudiadas en el 70,1% de los pacientes. No se<br/>observaron complicaciones graves asociadas al uso de la guía de presión.<br/>• Conclusiones: La integración de la guía intracoronaria de presión en la práctica clínica habitual es factible y segura. La<br/>valoración funcional de lesiones moderadas mediante guía intracoronaria permite evitar el intervencionismo coronario en más<br/>del 70% de las lesiones estudiadas
520 8# - SUMMARY, ETC.
Summary, etc. • Introduction: The decision to perform a coronary revascularization is mainly based on angiographic imaging and on the<br/>patient’s clinical condition. Sometimes, these data are insufficient to decide on the treatment of a lesion. The intracoronary<br/>USO DE LA GUÍA DE PRESIÓN<br/>EN UN LABORATORIO DE<br/>HEMODINÁMICA<br/>Pág. 48/ Enfermería en Cardiología. 2015; Año XXII (65) ARTÍCULOS CIENTÍFICOS<br/>pressure guide wire allows to ascertain, at the cath-lab, the functional repercussions of a lesion, it being thereby possible to<br/>make decisions in situ without further delays or new catheterizations. The aim of this study is to present the results of the<br/>incorporation of the use of intracoronary pressure guide wires into a cath-lab usual practice.<br/>Methods: Unicentric observational study including consecutively all patients with angiographically-moderate coronary stenoses<br/>(visual stenosis as per diameter between 40-70%) studied with the use of a pressure guide wire between 01-01-2006 and<br/>05-31-2011.<br/>• Results: 784 lesions were studied in 683 patients. Average age: 68.03 ± 10.6 years; 72.2% were male, 74.7% had hypertension,<br/>54.3% had dyslipidemia, 40.3% had diabetes, 47.6% were smokers and 21.7% had suffered from an old infarction. The<br/>indication for coronariography was: 59.2% NSTEMI, 24.9% stable angina, 7.6% STEMI, 6.1% other. Studied vessels: 57.4%<br/>anterior descending artery, 21% right coronary artery, 19.8% circumflex artery, 1.8% others. FFR > 0.75 was observed in 602<br/>(76.3%) of the lesions studied (528 patients, 77.3%) . No angioplasty was performed in some of the lesions studied in 70.1%<br/>of patients. No serious complication associated with the use of the pressure guide wire was observed.<br/>• Conclusions: The incorporation of the intracoronary pressure guide wire into the current clinical practice is feasible and safe.<br/>Functional assessment of moderate lesions with an intracoronary guide wire allows to avoid coronary interventionism in more<br/>than 70% of the lesions studied.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term angioplastia
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term revascularización miocárdica
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term circulación coronaria
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term angioplasty
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term myocardial revascularization
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term coronary circulation
773 ## - HOST ITEM ENTRY
Related parts -- 2015, v. 22, n. 65, p. 47-51
Title Enfermería en Cardiología
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://www.enfermeriaencardiologia.com/wp-content/uploads/65_05.pdf">https://www.enfermeriaencardiologia.com/wp-content/uploads/65_05.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 13/01/2020   PP15 v22(65):47-51 13/01/2020 13/01/2020 Artículo de revista Cajonera

Powered by Koha