MARC details
000 -LEADER |
fixed length control field |
03367nas a22002177a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326104756.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2007 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
2603-8730 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 03 - TITLE STATEMENT |
Title |
La Frecuencia Respiratoria (FR), ¿una constante olvidada? / |
Statement of responsibility, etc. |
Judith Oliveros Val |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.31 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
La frecuencia respiratoria (FR) es un signo vital indispensable en la buena valoración diagnóstica y evolución física del paciente, especialmente en aquellos con problemas neumológicos (EAP, ASMA...); pero lejos de ello, la FR suele relegarse a un segundo plano no midiéndose con la misma asiduidad y rigor que el resto de los signos vitales, restándole así su importante relevancia clínica.<br/>Existen multitud de protocolos descritos para la medición de la FR, pero todos ellos establecen que dicha medición debe realizarse en un minuto entero.<br/>En este estudio, pretendemos observar si es posible reducir el tiempo de medición de dicha constante de 60 a 30 segundos (con la aplicación de un nuevo protocolo) sin que se vea afectado su valor final y pueda aplicarse a todos nuestros pacientes.<br/>Para ello, se realizó la toma de la FR en 60 y en 30 segundos (con la aplicación del nuevo protocolo) en 100 pacientes escogidos al azar.<br/>Los resultados obtenidos y procesados estadísticamente nos permitieron concluir que es posible reducir el tiempo de medida de 60 a 30 segundos sin que se vea afectado el valor final de la FR independientemente del sexo, hábito tabáquico y/o especialidad de nuestros pacientes, pudiendo así hacer extensible el uso del nuevo protocolo a todos los pacientes de nuestra unidad. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
The respiratory rate (FR) is an essential vital sign in the good diagnostic evaluation and physical evolution of the patient, especially in those with pneumological problems (PAD, ASTHMA ...); but far from it, the FR is usually relegated to the background not being measured with the same regularity and rigor as the rest of the vital signs, thus subtracting its important clinical relevance.<br/>There are a multitude of protocols described for the measurement of the FR, but all of them establish that said measurement must be carried out in a whole minute.<br/>In this study, we intend to observe whether it is possible to reduce the measurement time of said constant from 60 to 30 seconds (with the application of a new protocol) without affecting its final value and can be applied to all our patients.<br/>For this, the RF was taken in 60 and 30 seconds (with the application of the new protocol) in 100 randomly chosen patients.<br/>The results obtained and statistically processed allowed us to conclude that it is possible to reduce the measurement time from 60 to 30 seconds without affecting the final value of the FR regardless of sex, smoking and / or specialty of our patients, thus being able to do The use of the new protocol can be extended to all patients in our unit. |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2007, 2, p.27-31 |
Title |
Enfermería Científica Altoaragonesa. Revista Científica del Colegio Oficial de Enfermería de Huesca |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="https://www.colegioenfermeriahuesca.org/pdf/2007.pdf">https://www.colegioenfermeriahuesca.org/pdf/2007.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |