MARC details
000 -LEADER |
fixed length control field |
02604nas a22003017a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326124049.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2008 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Resultados preliminares de las placas que actúan como fijadores internos en el tratamiento de las fracturas supracondíleas de la extremidad distal del fémur (sistema LISS®) = |
Remainder of title |
Internal fixators plates preliminary results in distal femoral fractures treatment (LISS® system) / |
Statement of responsibility, etc. |
Sáez Martínez D, Vaquero Martín J, Esparragoza Cabrera L, García Rodríguez D |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p. 26-27 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivo: Las fracturas del fémur distal son lesiones potencialmente serias que representan el 7% de todas las fracturas de este hueso. Analizamos el comportamiento de los fijadores internos LISS®, que han acreditado tanto ventajas mecánicas como biológicas.<br/>Material y método: Revisamos retrospectivamente las placas LISS® en el tratamiento de las primeras 13 fracturas del fémur distal durante año y medio.<br/>Resultados: Obtuvimos altas tasas de consolidación (91%) y bajos porcentajes de desmontaje (9%). No hemos tenido ningún caso de infección ni necesidad de aplicar injerto.<br/>Conclusión: El sistema LISS se confirma como una alternativa de primera elección en el tratamiento de las fracturas de la extremidad distal del fémur, disminuyendo las complicaciones derivadas de los sistemas que requieren reducción abierta. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Objetive: distal femoral fractures are potentially serious injuries, we analyze the internal fixators like LISS; which has proved biological and mechanical advantages<br/>Material and method: we have reviewed our results with the first 13 distal femoral fractures treated by LISS® plate in one and half year.<br/>Results: we obtained high union rates (91%) and low dismantles rates (9%), without cases of infection or grafts.<br/>Conclusion: LISS has proved to be a first choice in distal femoral femur fractures decreasing open reduction systems complications. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fracturas del fémur distal |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Osteosíntesis |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
placa LISS |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
LISS |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
distal femoral fractures |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Internal fixators |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Osteosynthesis |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2008, v. 19, 1, p. 22-27 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v19n1/pdf/02_03.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v19n1/pdf/02_03.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |