Facultad de Enfermería y Fisioterapia Salus Infirmorum

Análisis biomecánico de la doble fijación híbrida en la columna lumbar = (Record no. 12538)

MARC details
000 -LEADER
fixed length control field 03072nas a22002897a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210326131900.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2008 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1888-6116
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Análisis biomecánico de la doble fijación híbrida en la columna lumbar =
Remainder of title Biomechanic analysis of a double hybrid fixation in the lumbar spine /
Statement of responsibility, etc. Cabello Gallardo J, Roca Burniol J, Iborra González M, Vázquez Solsona JJ
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 81-82
520 3# - SUMMARY, ETC.
Summary, etc. Objetivo: valorar la repercusión biomecánica de la doble fijación híbrida, rígida y dinámica, sobre el nivel suprayacente en la columna lumbar.<br/>Material y métodos: en 6 especimenes L3- S1 de columna vertebral de cadáver, se realizó la medición de la presión intradiscal (PID) en los discos L3-L4, L4-L5 y L5-S1, en tres condiciones diferentes: espécimen intacto, con fijación rígida en L5-S1 y doble fijación híbrida L4-S1. Las muestras fueron sometidos a cargas progresivas hasta alcanzar 750 N en compresión axial, flexión anterior y extensión.<br/>Resultados: en el disco L3-L4, suprayacente a la estabilización dinámica se produjo un incremento del 10% de la PID. En L4-L5 el implante dinámico consiguió un descenso del 50% de la PID y la PID del disco con instrumentación rígida L5-S1 se redujo en un 65%.<br/>Conclusión: la PID del segmento adyacente al implante dinámico es mucho menor que en las instrumentaciones rígidas. La estabilización dinámica aporta protección al disco por encima de la fusión rígida.
520 8# - SUMMARY, ETC.
Summary, etc. Objetive: to evaluate the biomechanics effects of the double hybrid fixation, rigid and dynamic, over the adjacent non-fixated level in the lumbar spine.<br/>Methods: using six specimens, L3-S1, from human lumbar spine, the measurement of the intradiscal pressure (IDP) in the disc L3-L4, L4-L5 and L5-S1, were performed in the following conditions: non-fixated specimen, with rigid fixation in L5-S1 and double hybrid fixation in L4-S1. The six specimens were subjected to progressive load until 750 N in axial compression, flexion and extension.<br/>Results: in the upper adjacent disc to the dynamic stabilization, L3-L4 disc, the IDP increased about 10%. In disc L4-L5 the posterior dynamic fixation the IDP decreased 50% and the IDP of disc with rigid fixation L5-S1 was reduced over 65%.<br/>Conclusion: the IDP of non-fixated segment adjacent to a dynamic implant is much lesser that in rigid fixations and the system provided protection to the disc over the rigid fixation
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term presión intradiscal
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term columna lumbar
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term estabilización dinámica
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term intradisc pressure
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term lumbar spine
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term dynamic stabilization
773 ## - HOST ITEM ENTRY
Related parts -- 2008, v. 19, 2, p. 74-82
Title Trauma
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v19n2/pdf/02_02.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v19n2/pdf/02_02.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 17/12/2019   PP14 v19(2):74-82 17/12/2019 17/12/2019 Artículo de revista Cajonera

Powered by Koha