MARC details
000 -LEADER |
fixed length control field |
02310nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326131939.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2008 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Colgajo braquiorraquial en la cobertura de la inserción distal del tendón del bíceps = |
Remainder of title |
Brachioradial flap for coverage of the distal insertion of the biceps tendon / |
Statement of responsibility, etc. |
Valbuena C, Ballesteros A, Cendagortagalarza J |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p. 197 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
El músculo braquiorradial es un músculo flexor accesorio del codo que también se puede utilizar para dar la cobertura sin provocar un déficit funcional. Está indicado en la cobertura de los defectos complejos de la cara anterior y lateral del codo, especialmente cuando existe exposición articular, y también del tercio proximal del antebrazo.<br/>Se presenta el caso de un varón de 49 años de edad con un problema de cobertura en la región anterior de codo tras una reinserción de bíceps distal 4 semanas antes, mediante anclaje en tuberosidad bicipital.<br/>El colgajo de músculo braquiorradial es seguro, está bien vascularizado y es fácil de realizar, con una mínima morbilidad. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
The brachioradial muscle is an accesory flexor muscle of the elbow that may also be used for coverage without causing functional deficit. It is indicated for covering complex defects in the anterior and lateral aspects of the elbow, particularly when joint exposure exists, and also in the proximal third of the forearm.<br/>The case of a 49-year-old male with a coverage problem in the anterior elbow region 4 weeks after distal biceps reinsertion by anchoring in the bicipital tuberosity is reported.<br/>The brachioradial muscle flap is safe, well vascularized, and easy to perform with minimum morbidity. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
codo |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
colgajo braquio-radial |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
defecto cutáneo |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
elbow |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
brachioradial flap |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
skin defect |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2008, v. 19, 3, p. 195-197 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v19n3/pdf/02_10.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v19n3/pdf/02_10.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |