MARC details
000 -LEADER |
fixed length control field |
03118nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326152559.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2009 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Osteotomía correctora tras lesiones de la fisis del radio distal en niños: técnica quirúrgica y resultados = |
Remainder of title |
Corrective osteotomy following damage of the distal radial physis in children: surgical technique and results / |
Statement of responsibility, etc. |
Kaempf de Oliveira R, Delgado Serrano P J |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p. 115 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Se presentan dos casos de cierre de la fisis distal del radio en niños que desarrollaron una deformidad grave de la muñeca (acortamiento del radio >2,5 cm). Fueran tratados quirúrgicamente en un solo tiempo mediante osteotomía correctora por vía de abordaje volar, fijación con placa volar de ángulo fijo y aporte de injerto óseo de cresta iliaca. Tras un seguimiento medio de 18 meses, ambos pacientes se encuentran asintomáticos y sin deformidad aparente.<br/>Son pocas las descripciones del uso de esta técnica en el tratamiento de las deformidades por epifisiodesis precoz. El uso de sistemas de fijación para el radio con placas de bloqueo de ángulo fijo permite alargar el radio a demanda tras la osteotomía, utilizando el conjunto formado por la placa y clavos de bloqueo distal como espaciador, y así colocar el injerto de cresta iliaca tricortical tallado a demanda del defecto. La liberación de partes blandas, como el periostio dorsal y el tendón del músculo braquiorradial, permite un alargamiento óseo adecuado, en un sólo tiempo quirúrgico. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Two cases of distal radial physis closure in children developing severe wrist deformity (radial shortening > 2.5 cm) are presented. Single-step surgery was carried out in the form of a corrective osteotomy adopting the volar approach, with fixed-angle volar plate fixation and bone grafting from the iliac crest. After an average 18 months of follow-up, both patients are asymptomatic and show no apparent deformity.<br/>There have been few descriptions of the use of this technique in the management of deformities related to early epiphysiodesis.<br/>The use of fixation systems for the radius, using fixed-angle locking plates, allows radius lengthening adjusted to demand following osteotomy, employing the combination of the plate and distal locking pins as spacer –with custom-sized tricortical iliac crest grafting within the defect. The freeing of soft parts such as the dorsal periosteum and brachioradialis muscle tendon allows adequate bone lengthening in a single surgical step. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
epifisiodesis |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
radio distal |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
osteotomía |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
epiphysiodesis |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
distal radius |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
osteotomy |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2009, v. 20, 2, p.108-115 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v20n2/pdf/02_07.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v20n2/pdf/02_07.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |