MARC details
000 -LEADER |
fixed length control field |
04127nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210326153058.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2009 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Resultados del tratamiento de las fracturas de radio distal con placa volar de ángulo fijo = |
Remainder of title |
Results of the treatment of distal radius fractures with fixed-angled volar plates / |
Statement of responsibility, etc. |
Sánchez Márquez J M, Cruz Pardos A, Ibarzábal Gil A |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p. 160 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivo: Determinar los resultados funcionales de pacientes con fractura del radio distal desplazada e inestable tratados mediante placa volar.<br/>Pacientes y metodología: Revisamos 34 pacientes consecutivos tratados con placa volar de ángulo fijo que fueron evaluados en la última visita de seguimiento utilizando las escalas DASH y Mayo Wrist Score. El seguimiento medio fue de 28 meses (12-70).<br/>Resultados: Las radiografías del postoperatorio inmediato mostraron una discrepancia radiocubital media de 1,5 mm, la inclinación radial media fue de 15º y la inclinación volar media de 5º. En el momento de la consolidación de la fractura, la discrepancia radiocubital media fue de 0,8 mm, la inclinación radial media fue de 13º y la inclinación volar media de 5º. La movilidad media de la muñeca afecta era de 65º de flexión, 60º de extensión, 21º de desviación radial y 34º de desviación cubital. La pronación media del lado afecto fue del 90% de la del lado contralateral, la supinación comparativa fue del 91%, y la fuerza de agarre en el lado afecto era de 16,85 y en el lado no afecto de 21,04. Al final del seguimiento, el valor medio de la escala DASH fue de 13,53<br/>y se obtuvieron 11 resultados excelentes, 15 buenos, 5 aceptables y 3 pobres utilizando la escala de Mayo.<br/>Conclusión: El tratamiento de las fracturas de radio distal mediante placa volar en una alternativa segura, que<br/>permite una reducción estable, con buenos resultados funcionales y radiológicos con pocas complicaciones. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Purpose: to determine the functional outcomes of patients treated with volar plating for displaced and unstable distal radius fractures.<br/>Materials and methods: we reviewed the records of 34 consecutive patients treated with volar plating in our institution. Outcomes were evaluated at the latest follow-up examination with the Disabilities of the Arm, Shoulder and Hand score and the Mayo Wrist Score.<br/>The average follow-up period was 28 months (range, 12-70).<br/>Results: radiographs in the immediate postoperative period showed a mean radial height of 1,5 mm, mean radial inclination was 15º and mean volar tilt was 5º.At fracture healing the mean radial height was 0,8 mm,<br/>mean radial inclination was 13º and mean volar tilt was 5º. The average affected wrist range of motion consisted of 65º of flexion (range, 35-90), 60º of extension (range, 30-90), 21º of radial deviation (range, 0-60), and 34º of ulnar deviation (range, 10-60). On average the pronation was 90,32% of the pronation of the contralateral extremity, the comparative supination was 91%, and the grip strength in the affected side was 16,85 and in the contralateral side was 21,04. The average score on the DASH was 13,53 at the latest follow-up evaluation, and the Mayo Wrist Score reported 11 excellent outcomes, 15 good, 5 fair and 3 poor outcomes.<br/>Conclusions: Treatment of distal radius fractures by means of a volar plate is a safe alternative that permits a stable reduction. Good functional and radiological results can be obtained with few complications. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fractura de radio distal |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
placa volar |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
prono-supinación |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
distal radius fracture |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
volar plate |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
prono-supination |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2009, v. 20, 3, p.156-160 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v20n3/pdf/02_05.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v20n3/pdf/02_05.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |