MARC details
000 -LEADER |
fixed length control field |
03538nas a22002897a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210406171723.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2010 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Resultados clínicos y laborales de las fracturas de la extremidad proximal del humero tratada con placas PHILOS® = |
Remainder of title |
Clinical-laboral results of proximal humerus fracture treated with PHILOS® plates fixation / |
Statement of responsibility, etc. |
García de las Heras B, Capilla Ramírez P, García de Lucas F |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.14 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivo: Valorar el resultado clínico y laboral de la osteosíntesis con placa PHILOS® en las fracturas de la extremidad proximal del húmero.<br/>Pacientes y método: Estudio retrospectivo de 16 pacientes con fractura desplazada de la extremidad proximal del húmero intervenidos con osteosíntesis mediante placa PHILOS®. La edad media fue de 42 (rango: 16-59) años, el 62% eran varones, el hombro dominante se afectó en el 38% de los casos. Estudiamos el tipo de fractura según la clasificación de Neer, valoración clínica, valoración funcional y resultados laborales.<br/>Resultados: El tiempo medio hasta la cirugía fue de 13 dias, el tiempo medio de rehabilitación de 6 meses y medio y el tiempo medio de baja de 7 meses. La puntuación en el test de Constant fue 73.3 (27-100), siendo peor en los pacientes con fractura luxación. Se incorporaron a su trabajo habitual 10 de los 16 pacientes.<br/>Conclusión: La osteosíntesis con placa PHILOS es un método eficaz en el tratamiento de las fracturas de la extremidad proximal del húmero, con buenos resultados tanto clínicos, como laborales.<br/>Nivel de evidencia: Estudio terapéutico, serie de casos, Nivel IV. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Aim: The assessment of PHILOS plate fixation for displaced proximal humeral fractures clinical and laboral outcomes.<br/>Patients and method: A retrospective study, 16 patients with fractures of the proximal humerus underwent to Philos plate fixation from January 2007 to December 2008 at the Hospital Majadahonda Fremap. Type of fracture according to Neer classification, clinical assessment, functional assessment and laboral result were studied.<br/>Results: The average age was 42 (range: 16-59), 62% were males, and the dominant shoulder was affected in 38% of cases. The mean time to surgery was 13 days, the average rehabilitation time of 6.5 months and mean time on sick leave is of 7.5 months. Three patients required additional treatments (mobilization under anesthesia, removal of osteosynthesis material and one patient required both procedures) only. Constant test score was 73.3 (range: 27-100), being worse in patients with fracture dislocation. 10 of the 16 patients returned to their usual work.<br/>Concluding remarks: The Plate Philos is an effective method in the treatment of fractures of the proximal humerus, showing good results both regarding clinical and occupational outcomes.<br/>Level of Evidence: Therapeutic study, level IV (case series). |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fractura extremidad superior humero |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
placa Philos |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
test de Constant. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
proximal fracture humerus |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
plate Philos |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
constant test |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2010, v. 21, 1, p. 11-14 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v21n1/pdf/02_02.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v21n1/pdf/02_02.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |