Facultad de Enfermería y Fisioterapia Salus Infirmorum

Resultados funcionales en fracturas de extremidad distal del radio. Tratamiento quirúrgico con placa DVR o tratamiento ortopédico = (Record no. 12416)

MARC details
000 -LEADER
fixed length control field 03667nas a22002657a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210414160642.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2011 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1888-6116
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Resultados funcionales en fracturas de extremidad distal del radio. Tratamiento quirúrgico con placa DVR o tratamiento ortopédico =
Remainder of title Functional results in fractures of distal radius. Surgical treatment Vs DVR plate orthopedic treatment /
Statement of responsibility, etc. Fernández León RA, Moreno Palacios JA, Rodríguez Oyaga A, Peces González N, Ruiz Molina D, García Delgado I
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.89-90
520 3# - SUMMARY, ETC.
Summary, etc. Objetivo: Comparar el resultado funcional del tratamiento conservador mediante reducción cerrada y yeso con la reducción abierta y colocación del sistema placa volar anatómica DVR, en fracturas de EDR después de rehabilitación.<br/>Material y método: Estudio retrospectivo de 70 pacientes con 54 años de edad media que sufrieron fractura de EDR. Treinta y cinco fueron tratados conservadoramente y otros 35 con placa DVR. Todos realizaron tratamiento rehabilitador y se valoraron los resultados funcionales a partir del año de la intervención, utilizando la escala de Mayo Wrist Score (MWS). El recorrido articular se midió mediante goniómetro manual y la fuerza con la Escala Cifrada Internacional<br/>Resultados: El tiempo desde la intervención hasta que se inició la rehabilitación fue de 57 días de media, con un promedio de 29 sesiones. El resultado funcional mostró un valor medio con la MWS de 88,43/100, al año de la fractura, considerado bueno, sin demostrar diferencias estadísticamente significativas entre los 2 grupos.<br/>La reinserción laboral de los sujetos que trabajaban en su antiguo trabajo fue de 88,9%.<br/>Conclusiones: El tratamiento de las fracturas de EDR seguido de tratamiento rehabilitador permite una buena recuperación funcional con independencia del tratamiento
520 8# - SUMMARY, ETC.
Summary, etc. Objetive: Compare the functional outcome of conservative management by closed reduction and cast with open reduction and placement of anatomical volar plate system DVR, in EDR fractures after rehabilitation.<br/>Material and Methods: We plan a retrospective study of 70 patients with a mean age of 54 years who suffered a EDR fracture, 35 patient treated conservatively and 35 treated by plate DVR. All carried out rehabilitation treatment and functional outcomes were assessed from the year of the intervention, using the scale de Mayo Wrist Score (MWS). The range of movement was measured by manual goniometer and strength with the scale by international standards.<br/>Results: The time from intervention until the beginning of the rehabilitation was 57 days on average, by an average of 28.97 sessions. The functional outcome showed a mean of 88.43/100 with MWS, a year after the fracture, considered good, without showing statistically significant differences between the two groups. The reemployment of individuals who worked in his old job was 88.9%.<br/>Conclusions: The treatment of fractures of EDR followed by rehabilitation treatment allows a good functional recovery independent of the treatment.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term rehabilitación de fracturas de radio
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term fractura extremidad distal del radio
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term rehabilitation radius fracture
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term distal radius fracture
773 ## - HOST ITEM ENTRY
Related parts -- 2011, v. 22, 2, p. 86-90
Title Trauma
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v22n2/pdf/02_03.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v22n2/pdf/02_03.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 03/12/2019   PP14 v22(2):86-90 03/12/2019 03/12/2019 Artículo de revista Cajonera

Powered by Koha