Facultad de Enfermería y Fisioterapia Salus Infirmorum

Estudio experimental sobre el patrón de penetración del cemento óseo en la artroplastia de rodilla según la técnica de cementación empleada = (Record no. 12381)

MARC details
000 -LEADER
fixed length control field 04020nas a22003137a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210414162412.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2012 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1888-6116
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Estudio experimental sobre el patrón de penetración del cemento óseo en la artroplastia de rodilla según la técnica de cementación empleada =
Remainder of title An experimental study of bone cement penetration in total knee arthroplasty depending on cementing technique used /
Statement of responsibility, etc. Pérez Mañanes R, Vaquero Martín J, Villanueva Martínez M
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.57-58
520 3# - SUMMARY, ETC.
Summary, etc. Objetivo: Evaluar la distribución y penetración del manto de cemento óseo en la artroplastia de rodilla según la técnica de cementación empleada.<br/>Material y método: Se cementaron las piezas en el segundo y quinto minuto según dos técnicas: presurización digital directa sobre el modelo (técnica M) o sobre la prótesis (técnica P). Se analizaron digitalmente las fotografías de los modelos cementados, determinando la longitud del manto de cemento, el porcentaje y la media de penetración.<br/>Resultados: La mejor calidad del manto de cemento se obtuvo con la técnica M aplicada en el segundo minuto, que logró una penetración media de 4,44 mm y un porcentaje de penetración del 79,36%; la técnica P en el quinto minuto tuvo el peor resultado (2,12 mm y 45,79%), siendo estas diferencias significativas (p=0,029).<br/>Los planos de corte tangencial (anterior y posterior) resultaron ser los peor cementados, con una media de penetración de 2 mm. La técnica M consiguió la mayor longitud de cemento en estos dos planos (35 mm y 17,9 mm), mientras que la técnica P cubrió menos del 50% de la longitud del corte (p=0,01).<br/>Conclusión: La cementación con presurización digital sobre la superficie ósea consigue mayor profundidad y porcentaje de penetración que la cementación sobre la prótesis. Los cortes femorales tangenciales (anterior y posterior) se cementan de forma precaria si se aplica sobre el implante
520 8# - SUMMARY, ETC.
Summary, etc. Objective: To assess the distribution and penetration of the cement mantle in knee arthroplasty depending on technique used.<br/>Material and method: Parts were cemented in the second and fifth minute using two techniques: digital pressurization (fingerpacking) directly over the model (technique M) or over the implant (technique P). We analyze digitally the photographs of the cemented models determining length of the cement mantle, percentage penetration and mean penetration.<br/>Results: The best quality of cement mantle was obtained with the technique M applied in the second minute, which achieved a mean penetration of 4.44 mm and a percentage penetration of 79.36%; technique P in the fifth minute obtained poorer result (2.12 mm and 45.79%), these differences being significant (p = 0.029).<br/>The tangential planes (anterior and posterior) proved to be poorer cemented, with a mean penetration of 2 mm. The technique M obtained the longest cement mantle in these two planes (35 mm and 17.9 mm), while tehnique P covered < 50% of the length of the plane (p = 0.01).<br/>Conclusions: Fingerpacking pressurization over the bone surface achieves a greater depth and percentage penetration of the cement mantle than cementing over the prosthetic implant. Tangential femoral cuts (anterior and posterior) are fixed unstably if it is cemented over the implant.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term artroplastia total de rodilla
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term cemento óseo
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term análisis digital
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term modelo sintético
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term total knee arthroplasty
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term bone cement
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term digital analysis
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term synthetic model
773 ## - HOST ITEM ENTRY
Related parts -- 2012, v. 23, n. 1, p. 48-58
Title Trauma
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v23n1/docs/Articulo6.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v23n1/docs/Articulo6.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 29/11/2019   PP14 v23(1):48-58 29/11/2019 29/11/2019 Artículo de revista Cajonera

Powered by Koha