MARC details
000 -LEADER |
fixed length control field |
04020nas a22003137a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210414162412.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2012 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Estudio experimental sobre el patrón de penetración del cemento óseo en la artroplastia de rodilla según la técnica de cementación empleada = |
Remainder of title |
An experimental study of bone cement penetration in total knee arthroplasty depending on cementing technique used / |
Statement of responsibility, etc. |
Pérez Mañanes R, Vaquero Martín J, Villanueva Martínez M |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.57-58 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivo: Evaluar la distribución y penetración del manto de cemento óseo en la artroplastia de rodilla según la técnica de cementación empleada.<br/>Material y método: Se cementaron las piezas en el segundo y quinto minuto según dos técnicas: presurización digital directa sobre el modelo (técnica M) o sobre la prótesis (técnica P). Se analizaron digitalmente las fotografías de los modelos cementados, determinando la longitud del manto de cemento, el porcentaje y la media de penetración.<br/>Resultados: La mejor calidad del manto de cemento se obtuvo con la técnica M aplicada en el segundo minuto, que logró una penetración media de 4,44 mm y un porcentaje de penetración del 79,36%; la técnica P en el quinto minuto tuvo el peor resultado (2,12 mm y 45,79%), siendo estas diferencias significativas (p=0,029).<br/>Los planos de corte tangencial (anterior y posterior) resultaron ser los peor cementados, con una media de penetración de 2 mm. La técnica M consiguió la mayor longitud de cemento en estos dos planos (35 mm y 17,9 mm), mientras que la técnica P cubrió menos del 50% de la longitud del corte (p=0,01).<br/>Conclusión: La cementación con presurización digital sobre la superficie ósea consigue mayor profundidad y porcentaje de penetración que la cementación sobre la prótesis. Los cortes femorales tangenciales (anterior y posterior) se cementan de forma precaria si se aplica sobre el implante |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Objective: To assess the distribution and penetration of the cement mantle in knee arthroplasty depending on technique used.<br/>Material and method: Parts were cemented in the second and fifth minute using two techniques: digital pressurization (fingerpacking) directly over the model (technique M) or over the implant (technique P). We analyze digitally the photographs of the cemented models determining length of the cement mantle, percentage penetration and mean penetration.<br/>Results: The best quality of cement mantle was obtained with the technique M applied in the second minute, which achieved a mean penetration of 4.44 mm and a percentage penetration of 79.36%; technique P in the fifth minute obtained poorer result (2.12 mm and 45.79%), these differences being significant (p = 0.029).<br/>The tangential planes (anterior and posterior) proved to be poorer cemented, with a mean penetration of 2 mm. The technique M obtained the longest cement mantle in these two planes (35 mm and 17.9 mm), while tehnique P covered < 50% of the length of the plane (p = 0.01).<br/>Conclusions: Fingerpacking pressurization over the bone surface achieves a greater depth and percentage penetration of the cement mantle than cementing over the prosthetic implant. Tangential femoral cuts (anterior and posterior) are fixed unstably if it is cemented over the implant. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
artroplastia total de rodilla |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
cemento óseo |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
análisis digital |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
modelo sintético |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
total knee arthroplasty |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
bone cement |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
digital analysis |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
synthetic model |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2012, v. 23, n. 1, p. 48-58 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v23n1/docs/Articulo6.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v23n1/docs/Articulo6.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |