Facultad de Enfermería y Fisioterapia Salus Infirmorum

Simulación del comportamiento mecánico de la fijación del fascículo posterolateral con tornillo biocompatible en reparaciones de ligamento cruzado anterior = (Record no. 12369)

MARC details
000 -LEADER
fixed length control field 03484nas a22003137a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210414165540.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2012 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 1888-6116
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Simulación del comportamiento mecánico de la fijación del fascículo posterolateral con tornillo biocompatible en reparaciones de ligamento cruzado anterior =
Remainder of title Mechanical behavior simulation of the posterolateral fascicle fixation by means of a biocompatible screw for anterior cruciate ligament repairs /
Statement of responsibility, etc. Jorge Rellán J, Guerrero Rosales MA, Vigil Castiello FJ, Álvarez Iglesias B, Maestro Fernández A, Fernández Lombardía J, Paz Aparicio A, Rodríguez López L, García González P, Fernández Lombardía MI
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p.82-83
520 3# - SUMMARY, ETC.
Summary, etc. Objetivo: Determinar, mediante simulación con elementos finitos (MEF), la adecuación de la fijación con tornillo biocompatible del fascículo posterolateral (PL) en las reparaciones de ligamento cruzado anterior (LCA) con técnica bifascicular y único túnel tibial.<br/>Material y método: Se realizó un estudio mediante MEF de las tensiones sufridas del material de fijación (Endobutton® y Biosure HA®) y del componente óseo en reparaciones del LCA mediante la técnica bifascicular y único túnel tibial.<br/>Resultados: Las fuerzas ejercidas sobre las fijaciones sobre el componente óseo están dentro de los límites admisibles por el hueso y por los materiales de fabricación de las fijaciones, tanto en la zona de anclaje como en fémur distal.<br/>Conclusión: La fijación del fascículo PL con un tornillo biocompatible en la reconstrucción del LCA con técnica bifascicular y único túnel tibial asegura un comportamiento mecánico adecuado para cuando la rodilla del paciente va a ser intensivamente rehabilitada.
520 8# - SUMMARY, ETC.
Summary, etc. Objective: To determine, through finite element simulation (FEM), the adaptation of the posterolateral (PL) fascicle fixation by means of a biocompatible screw for anterior cruciate ligament (ACL) repairs when using the bifascicular technique with a single tibial tunnel.<br/>Material and method: It has been performed a finite element study in order to analyse the stress suffered by both material fixation (Endobutton® and Biosure HA®), and the bone component in ACL repairs using the bifascicular technique with a single tibial tunnel.<br/>Results: The simulation carried out shows that the forces exerted over the fixations and the bone are within the allowable limits for the bone and the manufacture material of the fixing devices, both at the anchorage area and at distal femur.<br/>Conclusion: The fixation of the PL fascicle by means of a biocompatible screw Biosure HA® in ACL repairs, when using the bifascicular technique with a single tibial tunnel, allows ensuring a proper mechanical behaviour when patient's knee is going to be intensively rehabilitated.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term rodilla
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term ligamento cruzado anterior
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term tornillo interferencia
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term MEF
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term knee
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term anterior cruciate ligament
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term interference screw
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term FEM
773 ## - HOST ITEM ENTRY
Related parts -- 2012, v. 23, n. 2, p. 77-83
Title Trauma
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v23n2/docs/Articulo2.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v23n2/docs/Articulo2.pdf</a>
Link text Acceso al documento
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 29/11/2019   PP14 v23(2):77-83 29/11/2019 29/11/2019 Artículo de revista Cajonera

Powered by Koha