MARC details
000 -LEADER |
fixed length control field |
02126nas a22003137a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210419171007.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2012 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Enclavado intramedular en fractura de fémur proximal: rotura doble con sistemas de implante distintos = |
Remainder of title |
Intramedullary nailing in proximal femur fracture: double breakage with different implants / |
Statement of responsibility, etc. |
Sanjuan Cerveró R, Franco Ferrando N, Jover Carrillo A |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.170-171 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Presentamos un caso clínico de una doble rotura de clavo en el cual los errores en la técnica quirúrgica pueden explicar, en parte, la causa del fallo de los implantes. Finalmente se resolvió la fractura con el uso de una placa de osteosíntesis con un contrafuerte. Aunque el enclavado intramedular es una de las técnicas más frecuentemente realizadas en COT, tenemos que utilizar una técnica quirúrgica lo más cuidadosa posible, prestando atención para evitar problemas que puedan complicar la evolución. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
We present a clinical report of a double failure in which errors in surgical technique can explain, in part, the cause of the breakage of the nails. Finally we resolved the fracture with an osteosynthesis plate with a strut.<br/>Although intramedullary nailing is one of the most frequent techniques in orthopedics, we have to use the most accurate technique and pay attention to avoid surgical problems that can complicate the evolution of the healing of the fractures of the hip. |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
clavo intramedular |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
rotura |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fractura subtrocantérea |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fémur |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
intramedulary nail |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
breakage |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
subtrocantheric fracture |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
femur |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2012, v. 23, n. 3, p. 168-171 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v23n3/docs/Articulo6.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v23n3/docs/Articulo6.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |