MARC details
000 -LEADER |
fixed length control field |
02909nas a22003377a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210419171020.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2012 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1888-6116 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Enclavado percutáneo de fracturas complejas intraarticulares de la extremidad distal del radio. A propósito de dos casos = |
Remainder of title |
Percutaneous pinning in complex intraarthicular fractures of the distal radius. Report of two cases / |
Statement of responsibility, etc. |
Hernández Pascual C, Benito del Carmen F, Ríos Luna A, Villanueva Martínez M |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.166-167 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivo: Señalar el buen resultado con enclavijado percutáneo combinado de estas lesiones y analizar la literatura al respecto.<br/>Pacientes y metodología: Presentamos dos casos de fractura compleja e intraarticular de la extremidad distal del radio, tratadas mediante enclavijado percutáneo con agujas de Kirschner. Seguimiento anual. Valoración radiológica y funcional.<br/>Resultados: Evolución muy satisfactoria, uno con mínima limitación en la movilidad y ambos con algodistrofia, con total recuperación. Los dos se reintegraron a sus trabajos previos.<br/>Conclusión: Con calidad ósea subyacente, este tratamiento es idóneo por sencillez, rapidez y economía, pudiendo realizarse incluso por un único cirujano. Por contra, precisa un exhaustivo seguimiento postoperatorio e inmovilización temporal. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Objective: To note the good results with combined percutaneous pinning of these lesions and to analyze literature related to this topic.<br/>Material and method: We present two cases with complex and intra-articular distal radius fractures, treated by percutaneous pinning with Kirschner wires. Anual follow-up. Radiological and functional outcomes.<br/>Results: Quite good evolution, one with minimal mobility limitation and both with algodystrophy with total recovery. Both returned to previous works.<br/>Conclusion: If the bone has a good quality, this orthopedic fixation device is useful because it is simply, fast and a low-cost method. One surgeon can do it alone. On the other hand, it needs an exhaustive postoperative follow-up and a cast is imperative during a variable period |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
fractura de radio |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
agujas de Kirschner |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
sistema de fijación ortopédica |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
resultados |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
distrofia simpático refleja |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
radius fracture |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
Kirschner wires |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
orthopedic fixation devices |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
treatment outcome |
653 14 - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
reflex sympathetic dystrophy |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2012, v. 23, n. 3, p. 162-167 |
Title |
Trauma |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="http://www.mapfre.com/fundacion/html/revistas/trauma/v23n3/docs/Articulo5.pdf">http://www.mapfre.com/fundacion/html/revistas/trauma/v23n3/docs/Articulo5.pdf</a> |
Link text |
Acceso al documento |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |