Mascarilla Laríngea = (Record no. 12129)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01839nas a22002057a 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20210423142841.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
fixed length control field | m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 171219t2003 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER | |
International Standard Serial Number | 0210-5020 |
040 ## - CATALOGING SOURCE | |
Transcribing agency | Salus Infirmorum |
245 00 - TITLE STATEMENT | |
Title | Mascarilla Laríngea = |
Remainder of title | Laryngeal mask / |
Statement of responsibility, etc. | Beatriz Alfonso Radío, María Esther Mos Reguera, María José Villaverde Rozados, María José Fernández Díaz, María Concepción González Argibay, Sandra Sixto Gato |
500 ## - GENERAL NOTE | |
General note | Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliografía: p. 48 |
520 3# - SUMMARY, ETC. | |
Summary, etc. | La mascarilla laríngea (ML) es un dispositivo muy útil tanto en el manejo de la vía aérea fácil como difícil. Se coloca en la faringe y permite la ventilación del paciente en distintas modalidades, espontánea o mecánica. Existen diferentes modelos, algunos incluso posibilitan la intubación endotraqueal a su través. Destacar que no asegura ni aísla la vía aérea. Como ventajas reseñar su fácil colocación, siendo una alternativa en la vía aérea difícil, por lo que es necesario su conocimiento y manejo por todos los profesionales que asistan la vía aérea |
520 8# - SUMMARY, ETC. | |
Summary, etc. | The laryngeal mask (ML) is a very useful device for both easy and difficult airway management. It is placed in the pharynx and allows ventilation of the patient in different modalities, spontaneous or mechanical. There are different models, some even enable endotracheal intubation through it. Note that it does not insure or isolate the airway. As advantages to review its easy placement, being an alternative in the difficult airway, so its knowledge and management is necessary by all professionals who assist the airway |
773 ## - HOST ITEM ENTRY | |
Related parts | -- 2003 v.26, 11, p 46-48 |
Title | Rol. Revista de Enfermería |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Universal Decimal Classification |
Koha item type | Artículo de revista |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Home library | Current library | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Price effective from | Koha item type | Public note |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Universal Decimal Classification | Non-fiction | Revistas y artículos | Revistas y artículos | 28/10/2019 | PP7 | 26(11):46-48 | 28/10/2019 | 28/10/2019 | Artículo de revista | Cajonera |