Facultad de Enfermería y Fisioterapia Salus Infirmorum

Eficacia del uso de Nobecutan En los vendajes compresivos radiales poscateterismo cardiaco = (Record no. 12039)

MARC details
000 -LEADER
fixed length control field 03333nas a22003017a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210426171850.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m|||||r|||| 00| 0
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field ta
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171219t2017 sp ||||| |||| 00| 0 spa |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0210-5020
040 ## - CATALOGING SOURCE
Transcribing agency Salus Infirmorum
245 00 - TITLE STATEMENT
Title Eficacia del uso de Nobecutan En los vendajes compresivos radiales poscateterismo cardiaco =
Remainder of title Impact of nobecutan use for radial compressive bandage after cardiac catheterization /
Statement of responsibility, etc. María Cruz Paesa, Yoana Jiménez Agesta, Adriana Ruiz Fernández, Verónica Pérez Ramírez, Begoña López Aranega, Fernando Muñárriz Bermudo
500 ## - GENERAL NOTE
General note Este artículo se encuentra disponible en su edición impresa.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliografía: p. 46
520 3# - SUMMARY, ETC.
Summary, etc. El cateterismo cardiaco es un procedimiento que consiste en la introducción de un catéter por un acceso arterial (femoral, radial, braquial, cubital) que se lleva hasta el corazón para su estudio anatómico y funcional, grandes vasos y arterias coronarias.<br/>En nuestro centro, en la actualidad, se utiliza el acceso arterial radial como primera elección. Cuando finalizamos el estudio se retira el catéter y hay que comprimir el punto de punción por el que hemos realizado la prueba. La hemostasia de la arteria radial tras el cateterismo la realizamos mediante vendaje compresivo con Tensoplast®.<br/>Nuestra experiencia previa en el uso de Nobecutan® aerosol en los vendajes compresivos femorales nos hizo extender su uso al nuevo acceso vascular radial.<br/>En nuestro estudio, queremos mostrar la eficacia del uso de Nobecutan®, para la protección cutánea de la zona de punción donde se coloca el vendaje compresivo radial. Los resultados muestran una reducción de la lesión dermatológica tras la retirada del vendaje, sobre todo en los pacientes bajo tratamiento antiagregante y en los que hayan presentado lesión dermatológica secundaria al rasurado en la zona de punción.
520 8# - SUMMARY, ETC.
Summary, etc. Cardiac catheterization is a procedure that involves the introduction of a catheter by an arterial access (femoral, radial, brachial, ulnar) that is carried to the heart for anatomical and functional study, large vessels and coronary arteries.<br/>In our center, today, radial arterial access is used as the first choice. When we finish the study, the catheter is removed and the puncture point at which we performed the test must be compressed. The hemostasis of the radial artery after catheterization is performed by compressive bandage with Tensoplast®.<br/>Our previous experience in the use of Nobecutan® spray on femoral compressive bandages made us extend its use to new radial vascular access.<br/>In our study, we want to show the effectiveness of the use of Nobecutan®, for skin protection of the puncture area where radial compressive bandage is placed. The results show a reduction in dermatological injury following removal of the bandage, especially in patients under-the-agon and in those who have had secondary dermatological injury to shaving in the puncture area.
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term acceso vascular
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term radial
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemostasia
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term catéter
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term vascular access
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term radial
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term hemostasis
653 14 - INDEX TERM--UNCONTROLLED
Uncontrolled term catheter
773 ## - HOST ITEM ENTRY
Related parts -- 2017 v.40, 1, p. 43-46
Title Rol. Revista de Enfermería
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Universal Decimal Classification
Koha item type Artículo de revista
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type Public note
    Universal Decimal Classification     Non-fiction Revistas y artículos Revistas y artículos 18/10/2019   PP7 v40(1):43-46 18/10/2019 18/10/2019 Artículo de revista Cajonera

Powered by Koha