MARC details
000 -LEADER |
fixed length control field |
04249nas a22002777a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210430110922.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2010 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0211-5638 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Relación entre el test de elevación de pierna recta y el test ángulo poplíteo en la medición de la extensibilidad isquiosural = |
Remainder of title |
Relationship between straight leg raise (SLR) and active knee extension (AKE) test measurements in hamstrings flexibility / |
Statement of responsibility, etc. |
Alejandro Luque Suárez, M.T. Fuente Hervías, Francisco Javier Barón López, María Teresa Labajos Manzanares |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.262-263 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivos<br/>Establecer la relación entre los test de elevación de pierna recta (EPR) y active knee extension (AKE, «ángulo poplíteo») en la medición de la extensibilidad isquiosural, determinar el grado de fiabilidad de cada test, determinar la influencia ejercida de un test sobre otro y establecer el grado de extensibilidad isquiosural en los universitarios, así como las diferencias entre géneros.<br/><br/>Material y método<br/>Se ha llevado a cabo un diseño experimental aleatorio transversal. 19 sujetos, 11 mujeres y 8 hombres, se presentaron voluntariamente al estudio. De ellos, 2 mujeres fueron excluidas por haber padecido dolor lumbar en el último mes. Fueron repartidos en dos grupos de forma aleatoria, un grupo fue sometido al test EPR seguido del AKE, mientras que el grupo 2 fue sometido al test AKE seguido del EPR, con 6min entre test y test, con dos intentos para cada test con 1min entre ensayo y ensayo.<br/><br/>Resultados<br/>No encontramos una relación estadísticamente significativa entre AKE y EPR, medida por un coeficiente de determinación del 0,420. En cuanto a fiabilidad, los resultados fueron 0,866 en AKE y de 0,741 en EPR. La realización de un test no condicionó el resultado del siguiente test y se hallaron resultados más altos en el hombre con respecto a la mujer.<br/><br/>Conclusión<br/>EPR y AKE no miden por igual la extensibilidad isquiosural, siendo AKE más fiable que EPR. Un test no influyó en la realización posterior del otro y se encontraron datos más altos de extensibilidad en hombres que mujeres, siendo necesaria más investigación para poder concluir sobre este aspecto. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Objective<br/>To determine the relationship between straight leg raise (SLR) test and active knee extension (AKE) in hamstrings flexibility measurement, reliability of each test, influence of one test over the other and establish the differences between the university students and gender in hamstrings range of motion.<br/><br/>Materials and methods<br/>A randomized, cross-sectional, experimental design study was conducted. Nineteen healthy subjects (11 women, 8 men) voluntarily participated in the study. Two women were excluded to de having had low back pain in the last month. The subjects were randomly assigned to groups 1 and 2. Group 1 performed the SLR first and then the KEA and Group 2 performed the KEA first and then the SLR. The subjects had 6min between the two test, with two attempts for each test with a one-minute rest period SLR1 and SLR2 and AKE1 and AKE2, respectively.<br/><br/>Results<br/>There was no statistically significant relationship between AKE and SLR measurements, with a coefficient of determination of 0.421. Reliability of SLR was 0.741 and 0.866 in AKE. No influence was found between both test and we found a higher range of movement in the male than in female.<br/><br/>Conclusions<br/>SLR and AKE does not measure hamstrings flexibility equally. We obtained more reliable results with the AKE. One test did not influence the subsequent performance of the other and higher data on extensibility were found in men than in women. However, future research is needed to make a conclusion on this aspect. |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
rodilla |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
cadera |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
rango de movimiento |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
knee |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
hip |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
range of movement |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2010 (nov/dic), v. 32, n. 6, p. 256-263 |
Title |
Fisioterapia. Revista de salud, discapacidad y terapéutica física. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |