MARC details
000 -LEADER |
fixed length control field |
04519nas a22003257a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210430111338.0 |
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS |
fixed length control field |
m|||||r|||| 00| 0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION |
fixed length control field |
ta |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
171219t2012 sp ||||| |||| 00| 0 spa | |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0211-5638 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
Salus Infirmorum |
245 00 - TITLE STATEMENT |
Title |
Análisis ecográfico de las modificaciones en la velocidad del flujo sanguíneo en la arteria vertebral producidas por el movimiento de rotación cervical máxima = |
Remainder of title |
Ultrasonography analysis of vertebral artery blood flow velocity changes on produced by the maximal cervical rotation / |
Statement of responsibility, etc. |
R. Pérez-Llanes, José Ríos-Díaz, Jacinto Javier Martínez Payá, M. E. Baño Aledo |
500 ## - GENERAL NOTE |
General note |
Este artículo se encuentra disponible en su edición impresa. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliografía: p.124 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
Objetivos<br/>Los test premanipulativos para la insuficiencia vertebrobasilar (TPIBV) suelen incorporar la rotación cervical para comprobar la solvencia de las arterias vertebrales (AV), aunque las investigaciones acerca del efecto de la rotación en el flujo de la AV discrepan y arrojan dudas en cuanto a la validez de las pruebas. Como un primer paso en esta línea el objetivo fue comprobar el efecto de la rotación cervical en los parámetros hemodinámicos de la AV en sujetos sanos.<br/><br/>Material y método<br/>Se contó con 10 mujeres voluntarias sanas de 18 a 23 años (media: 20,3; DT: 1,64 años) a las que se le realizaron ecografías Doppler bilaterales en el segmento de la AV suboccipital (AV3) en la posición de rotación neutra, contralateral y homolateral. Se calcularon la velocidad del pico sistólico (VPS), velocidad del pico diastólico (VPD), velocidad media (VM) e índice de resistencia (IR). Los datos se analizaron con una ANOVA de medidas repetidas y las comparaciones se realizaron con la corrección de Bonferroni (SPSS v15.0; IC del 95%).<br/><br/>Resultados<br/>No se detectaron diferencias estadísticamente significativas en cuanto a la lateralidad y la rotación cervical ni en VPS (FVPS=0,935; p=0,47) ni en VPD (FVPD=1,067; p=0,39), ni en VM (FVM=1,172; p=0,34), ni en IR (FIR=1,183; p=0,33). Debe destacarse la baja potencia de los análisis (entre el 30 y el 38%) por lo que la ausencia de diferencias debe considerarse con precaución.<br/><br/>Conclusiones<br/>Los parámetros hemodinámicos de la AV no se modificaron en sujetos sanos con las rotaciones cervicales, cuestión que debe ser investigada en sujetos con insuficiencia vertebrobasilar. |
520 8# - SUMMARY, ETC. |
Summary, etc. |
Objectives<br/>The pre-manipulative vertebrobasilar insufficiency tests (PVBIT) generally incorporate cervical rotation to verify the solvency of the vertebral arteries (VA). However, research on the effect of rotation on VA blood flow differ and question the validity of the tests. The first aim of this study was to verify the effect of cervical rotation on the hemodynamic parameters of the VAs in healthy subjects.<br/><br/>Material and method<br/>Ten healthy female volunteers, aged 18 to 23 years (mean: 20.3, SD: 1.64 years), were subjected to bilateral Doppler ultrasonographies over the suboccipital segment of the AV (AV3) with neutral, contralateral and ipsilateral cervical rotation positions. We calculated peak systolic velocity (PSV), peak diastolic velocity (PDV), mean velocity (MV) and resistance index (RI). The data were analyzed with repeated measures ANOVA and comparisons were made with Bonferroni correction (SPSS v15.0, C.I. 95%).<br/><br/>Results<br/>No statistically significant differences were detected regarding lateralization or rotation in the values of PSV (FPSV=0.935, P=.47), or PDV (FPDV=1.067, P=.39), or MV (FMV=1.172, P=.34), or RI (FRI=1.183, P=.33). The low power of analysis (between 30 and 38%) should be noted and thus the absence of differences should be observed with caution.<br/><br/>Conclusions<br/>Hemodynamic parameters of the VA did not change with cervical rotations in healthy women so that this question should be studied in patients with vertebrobasilar insufficiency.<br/><br/> |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
arteria vertebral |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
insuficiencia vertebrobasilar |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
ultrasonografía Doppler |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
velocidad del flujo sanguíneo |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
vértebras cervicales |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
vertebral artery |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
vertebrobasilar insufficiency |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
doppler ultrasonography |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
blood flow velocity |
653 ## - INDEX TERM--UNCONTROLLED |
Uncontrolled term |
cervical vertebrae |
773 ## - HOST ITEM ENTRY |
Related parts |
-- 2012 (may/jun), v. 34, n. 3, p. 118-124 |
Title |
Fisioterapia. Revista de salud, discapacidad y terapéutica física. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Universal Decimal Classification |
Koha item type |
Artículo de revista |